A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually.
A vulnerability has been identified in the following Siemens industrial products: SIMATIC S7-200 Smart: All versions < V2.03.01, SIMATIC S7-400 PN V6: All versions < V6.0.6, SIMATIC S7-400 H V6: All versions < 6.0.8, SIMATIC S7-400 PN/DP V7: All versions, SIMATIC S7-410 V8: All versions, SIMATIC S7-300: All versions, SIMATIC S7-1200: All versions, SIMATIC S7-1500: All versions < 2.0, SIMATIC S7-1500 Software Controller: All versions < 2.0, SIMATIC WinAC RTX 2010 incl. F: All versions, SIMATIC ET 200AL: All versions, SIMATIC ET 200ecoPN: All versions, SIMATIC ET 200M: All versions, SIMATIC ET 200MP: All versions, SIMATIC ET 200pro: All versions, SIMATIC ET 200S: All versions, SIMATIC ET 200SP: All versions, DK Standard Ethernet Controller: All versions, EK-ERTEC 200P: All versions < V4.5, EK-ERTEC 200 PN IO: All versions, SIMOTION D: All versions < V5.1 HF1, SIMOTION C: All versions < V5.1 HF1, SIMOTION P: All versions < V5.1 HF1, SINAMICS DCM: All versions, SINAMICS DCP: All versions, SINAMICS G110M / G120(C/P/D) w. PN: All versions < V4.7 SP9 HF1, SINAMICS G130 and G150: All versions, SINAMICS S110 w. PN: All versions, SINAMICS S120: All versions, SINAMICS S150 V4.7 and V4.8: All versions, SINAMICS V90 w. PN: All versions, SINUMERIK 840D sl: All versions, SIMATIC Compact Field Unit: All versions, SIMATIC PN/PN Coupler: All versions, SIMOCODE pro V PROFINET: All versions, SIRIUS Soft starter 3RW44 PN: All versions. Specially crafted packets sent to port 161/UDP could cause a Denial-of-Service condition. The affected devices must be restarted manually.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
A vulnerability has been identified in the following Siemens industrial products: SIMATIC S7-200 Smart: All versions < V2.03.01, SIMATIC S7-400 PN V6: All versions < V6.0.6, SIMATIC S7-400 H V6: All versions < 6.0.8, SIMATIC S7-400 PN/DP V7: All versions, SIMATIC S7-410 V8: All versions, SIMATIC S7-300: All versions, SIMATIC S7-1200: All versions, SIMATIC S7-1500: All versions < 2.0, SIMATIC S7-1500 Software Controller: All versions < 2.0, SIMATIC WinAC RTX 2010 incl. F: All versions, SIMATIC ET
A vulnerability has been identified in SIMATIC S7-200 Smart, SIMATIC S7-400 PN V6, SIMATIC S7-400 H V6, SIMATIC S7-400 PN/DP V7, SIMATIC S7-410 V8, SIMATIC S7-300, SIMATIC S7-1200, SIMATIC S7-1500, SIMATIC S7-1500 Software Controller, SIMATIC WinAC RTX 2010 incl. F, SIMATIC ET200AL, SIMATIC ET200ecoPN, SIMATIC ET200M, SIMATIC ET200MP, SIMATIC ET200pro, SIMATIC ET200S, SIMATIC ET200SP, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PR
Initial Analysis by NIST1/11/2018 12:03:28 PM
Action
Type
Old Value
New Value
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5
OR
cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_pn\/pn_coupler:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.0
OR
cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.03.01
OR
cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 6.0.8
OR
cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-400pn\/dp_v7_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_s7-400pn\/dp_v7:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 6.0.6
OR
cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:* versions up to (including) 5.1
OR
cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:* versions up to (including) 5.1
OR
cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:* versions up to (including) 5.1
OR
cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_g110m\/g120pn_firmware:*:*:*:*:*:*:*:* versions up to (including) 4.7
OR
cpe:2.3:h:siemens:sinamics_g110m\/g120pn:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*
Added
CVSS V2
(AV:N/AC:L/Au:N/C:N/I:N/A:C)
Added
CVSS V3
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Added
CWE
CWE-19
Changed
Reference Type
http://www.securityfocus.com/bid/101964 No Types Assigned
http://www.securityfocus.com/bid/101964 Third Party Advisory, VDB Entry
Changed
Reference Type
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf No Types Assigned