U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2017-2681

Change History

CVE Modified by CISA-ADP 6/16/2026 9:16:39 PM

Action Type Old Value New Value
Added SSVC

                  
                
              
{"timestamp":"2024-07-23T20:22:19.045364Z","id":"CVE-2017-2681","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by Siemens AG 6/16/2026 9:16:39 PM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","defaultStatus":"unknown","versions":[{"version":"All versions < V4.1.1 Patch04","status":"affected"}]},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","defaultStatus":"unknown","versions":[{"version":"All versions < V4.2.1 Patch03","status":"affected"}]},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","defaultStatus":"unknown","versions":[{"version":"All versions < V4.4.0 Patch01","status":"affected"}]},{"vendor":"Siemens","product":"IE/AS-i Link PN IO","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"IE/PB-Link (incl. SIPLUS NET variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.03","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE W-700 IEEE 802.11n family","defaultStatus":"unknown","versions":[{"version":"All versions < V6.1","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE X-200 family (incl. SIPLUS NET variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.2","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE X-200IRT family (incl. SIPLUS NET variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V5.4.0","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.1.0","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE X408 family","defaultStatus":"unknown","versions":[{"version":"All versions < V4.1.0","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE X414","defaultStatus":"unknown","versions":[{"version":"All versions < V3.10.2","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE XM-400 family","defaultStatus":"unknown","versions":[{"version":"All versions < V6.1","status":"affected"}]},{"vendor":"Siemens","product":"SCALANCE XR-500 family","defaultStatus":"unknown","versions":[{"version":"All versions < V6.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CM 1542-1","defaultStatus":"unknown","versions":[{"version":"All versions < V2.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CM 1542SP-1","defaultStatus":"unknown","versions":[{"version":"All versions < V1.0.15","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V2.1.82","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","defaultStatus":"unknown","versions":[{"version":"All versions < V2.1.82","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.0.15","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1543-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1543SP-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.0.15","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1604","defaultStatus":"unknown","versions":[{"version":"All versions < V2.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 1616","defaultStatus":"unknown","versions":[{"version":"All versions < V2.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 343-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V3.1.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Lean (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V3.1.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.17","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.17","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1 OPC UA","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC DK-16xx PN IO","defaultStatus":"unknown","versions":[{"version":"All versions < V2.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200AL IM 157-1 PN","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V1.0.2","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200M (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN BA","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.0.1","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-3 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-4 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN BA","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HS","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.0.1","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN: IO-Link Master","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET200S (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V15.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV420 SR-B","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV420 SR-B Body","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV420 SR-P","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV420 SR-P Body","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV440 HR","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV440 SR","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC MV440 UR","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC RF650R","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC RF680R","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC RF685R","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller","defaultStatus":"unknown","versions":[{"version":"All versions < V2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-200 SMART","defaultStatus":"unknown","versions":[{"version":"All versions < V2.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V3.X.14","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V6.0.7","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V6.0.6","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.0.2","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-410 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V8.2","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC TDC CP51M1","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V1.1.8","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC TDC CPU555","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V1.1.1","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Advanced","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Basic","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Standard","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinAC RTX 2010","defaultStatus":"unknown","versions":[{"version":"All versions < V2010 SP3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinAC RTX F 2010","defaultStatus":"unknown","versions":[{"version":"All versions < V2010 SP3","status":"affected"}]},{"vendor":"Siemens","product":"SIMOCODE pro V PROFINET (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V2.0.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMOTION","defaultStatus":"unknown","versions":[{"version":"All versions < V4.5 HF1","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS DCM w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V1.4 SP1 HF5","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS DCP w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V1.2 HF1","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G110M w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 SP6 HF3","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 SP6 HF3","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G130 V4.7 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 HF27","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G130 V4.8 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.8 HF4","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G150 V4.7 w. PN","defaultStatus":"unknown","versions":[{"version":"V4.7: All versions < V4.7 HF27","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS G150 V4.8 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.8 HF4","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S110 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.4 SP3 HF5","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 HF27","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.8 HF4","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S150 V4.7 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 HF27","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS S150 V4.8 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V4.8 HF4","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS V90 w. PN","defaultStatus":"unknown","versions":[{"version":"All versions < V1.01","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK 828D V4.5 and prior","defaultStatus":"unknown","versions":[{"version":"All versions < V4.5 SP6 HF2","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK 828D V4.7","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 SP4 HF1","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4.5 and prior","defaultStatus":"unknown","versions":[{"version":"All versions < V4.5 SP6 HF2","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4.7","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 SP4 HF1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.2.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V4.1.0","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS ACT 3SU1 interface module PROFINET","defaultStatus":"unknown","versions":[{"version":"All versions < V1.1.0","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Motor Starter M200D PROFINET","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Soft Starter 3RW44 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SITOP PSU8600 PROFINET","defaultStatus":"unknown","versions":[{"version":"All versions < V1.2.0","status":"affected"}]},{"vendor":"Siemens","product":"SITOP UPS1600 PROFINET (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V2.2.0","status":"affected"}]},{"vendor":"Siemens","product":"Softnet PROFINET IO for PC-based Windows systems","defaultStatus":"unknown","versions":[{"version":"All versions < V14 SP1","status":"affected"}]}]