This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Current Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 14.0
OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:* versions up to (excluding) 14.0
*cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:* versions up to (excluding) 14.0
*cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:* versions up to (excluding) 14.0
Added
CVSS V2
(AV:N/AC:M/Au:N/C:P/I:P/A:P)
Added
CVSS V2 Metadata
Victim must voluntarily interact with attack mechanism
Added
CVSS V3
AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Added
CWE
CWE-20
Changed
Reference Type
http://www.securityfocus.com/bid/105931 No Types Assigned
http://www.securityfocus.com/bid/105931 Third Party Advisory, VDB Entry
Changed
Reference Type