| Added |
Affected |
|
[{"vendor":"Siemens","product":"SIMATIC S7-400 CPU 414-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 CPU 414F-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 CPU 416-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 CPU 416F-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 343-1 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC CP 443-1 Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8FX PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.7.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller","defaultStatus":"unknown","versions":[{"version":"All versions < V1.7.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 CPU 412-2 PN V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V6.0.9","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V6.0.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-410 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V8.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinAC RTX 2010","defaultStatus":"unknown","versions":[{"version":"All versions < V2010 SP3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinAC RTX F 2010","defaultStatus":"unknown","versions":[{"version":"All versions < V2010 SP3","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK 828D","defaultStatus":"unknown","versions":[{"version":"All versions < V4.7 SP6 HF1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1 Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.16","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-400 CPU 414-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-400 CPU 416-3 PN/DP V7","defaultStatus":"unknown","versions":[{"version":"All versions < V7.0.3","status":"affected"}]},{"vendor":"Siemens","product":"Softnet PROFINET IO for PC-based Windows systems","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]}]
|