Current Description
An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents outside of the intended sphere of control, causing the software to embed incorrect documents into its output and expose restricted information.
Source:
MITRE
Description Last Modified:
12/24/2018
View Analysis Description
Analysis Description
An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents outside of the intended sphere of control, causing the software to embed incorrect documents into its output and expose restricted information.
Source:
MITRE
Description Last Modified:
12/24/2018
Impact
CVSS v3.0 Severity and Metrics:
Base Score:
7.5 HIGH
Vector:
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
(V3 legend)
Impact Score:
3.6
Exploitability Score:
3.9
Attack Vector (AV):
Network
Attack Complexity (AC):
Low
Privileges Required (PR):
None
User Interaction (UI):
None
Scope (S):
Unchanged
Confidentiality (C):
High
Integrity (I):
None
Availability (A):
None
CVSS v2.0 Severity and Metrics:
Base Score:
5.0 MEDIUM
Vector:
(AV:N/AC:L/Au:N/C:P/I:N/A:N)
(V2 legend)
Impact Subscore:
2.9
Exploitability Subscore:
10.0
Access Vector (AV):
Network
Access Complexity (AC):
Low
Authentication (AU):
None
Confidentiality (C):
Partial
Integrity (I):
None
Availability (A):
None
Additional Information:
Allows unauthorized disclosure of information
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because
they may have information that would be of interest to you. No inferences should be drawn on account of other sites
being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose.
NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further,
NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about
this page to nvd@nist.gov.
Technical Details
Vulnerability Type
(View All)
- Improper Restriction of XML External Entity Reference ('XXE') (CWE-611)
Change History
2 change records found
- show changes
Initial Analysis -
2/1/2019 12:29:06 PM
Action |
Type |
Old Value |
New Value |
Added |
CPE Configuration |
|
OR
*cpe:2.3:a:schneider-electric:iiot_monior:3.1.38:*:*:*:*:*:*:* |
Added |
CVSS V2 |
|
(AV:N/AC:L/Au:N/C:P/I:N/A:N) |
Added |
CVSS V3 |
|
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
Added |
CWE |
|
CWE-611 |
Changed |
Reference Type |
http://www.securityfocus.com/bid/106484 No Types Assigned |
http://www.securityfocus.com/bid/106484 Third Party Advisory |
Changed |
Reference Type |
https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/ No Types Assigned |
https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/ Vendor Advisory |
CVE Modified by MITRE -
1/10/2019 6:29:12 AM
Action |
Type |
Old Value |
New Value |
Added |
Reference |
|
http://www.securityfocus.com/bid/106484 [No Types Assigned] |