A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.
A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:hp:simplivity_2600_gen10_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.5 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_2600_gen10:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_380_gen10_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.1 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_380_gen10_g_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.8 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_380_gen9_firmware:*:*:*:*:*:*:*:* versions from (including) 3.6.2 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_omnicube_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_omnicube:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_omnistack_for_cisco_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_omnistack_for_cisco:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_omnistack_for_dell_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_omnistack_for_dell:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:hp:simplivity_omnistack_for_lenovo_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
OR
cpe:2.3:h:hp:simplivity_omnistack_for_lenovo:-:*:*:*:*:*:*:*
Added
CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:P/A:P)
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Added
CWE
NIST CWE-22
Changed
Reference Type
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst03956en_us No Types Assigned