Vulnerability Change Records for CVE-2019-6575

Change History

CVE Modified by CISA-ADP 6/16/2026 10:39:17 PM

Action Type Old Value New Value
Added SSVC

                  
                
              
{"timestamp":"2026-06-03T13:20:11.329732Z","id":"CVE-2019-6575","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by Siemens AG 6/16/2026 10:39:17 PM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"Siemens","product":"SIMATIC CP 443-1 OPC UA","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)","versions":[{"version":"All versions < V2.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)","versions":[{"version":"All versions < V15.1 Upd 4","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)","versions":[{"version":"All versions < V15.1 Upd 4","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F","versions":[{"version":"All versions < V15.1 Upd 4","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC IPC DiagMonitor","versions":[{"version":"All versions < V5.1.3","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC NET PC Software V13","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC NET PC Software V14","versions":[{"version":"All versions < V14 SP1 Update 14","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC NET PC Software V15","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC RF188C","versions":[{"version":"All versions < V1.1.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC RF600R family","versions":[{"version":"All versions < V3.2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":[{"version":"All versions >= V2.5 < V2.6.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller","versions":[{"version":"All versions between V2.5 (including) and V2.7 (excluding)","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC OA","versions":[{"version":"All versions < V3.15 P018","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Advanced","versions":[{"version":"All versions < V15.1 Upd 4","status":"affected"}]},{"vendor":"Siemens","product":"SINEC NMS","versions":[{"version":"All versions < V1.0 SP1","status":"affected"}]},{"vendor":"Siemens","product":"SINEMA Server","versions":[{"version":"All versions < V14 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK OPC UA Server","versions":[{"version":"All versions < V2.1","status":"affected"}]},{"vendor":"Siemens","product":"TeleControl Server Basic","versions":[{"version":"All versions < V3.1.1","status":"affected"}]}]