You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:a:silver-peak:ecos:*:*:*:*:*:*:*:* versions from (including) 8.1 up to (excluding) 8.1.9.15
*cpe:2.3:a:silver-peak:ecos:*:*:*:*:*:*:*:* versions from (including) 8.3.0 up to (excluding) 8.3.0.8
*cpe:2.3:a:silver-peak:ecos:*:*:*:*:*:*:*:* versions from (including) 8.3.1 up to (excluding) 8.3.1.2
*cpe:2.3:a:silver-peak:ecos:*:*:*:*:*:*:*:* versions from (including) 9.0 up to (excluding) 9.0.2.0
OR
cpe:2.3:a:silver-peak:vx-
Added
CVSS V2
NIST (AV:N/AC:M/Au:S/C:C/I:C/A:C)
Added
CVSS V2 Metadata
Victim must voluntarily interact with attack mechanism
Added
CVSS V3.1
NIST AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
Added
CWE
NIST CWE-78
Changed
Reference Type
https://www.silver-peak.com/support/user-documentation/security-advisories No Types Assigned
The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects ll current ECOS versions: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9
The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and
Quick Info
CVE Dictionary Entry: CVE-2020-12149 NVD
Published Date: 12/11/2020 NVD
Last Modified: 11/07/2023
Source: Silver Peak Systems, Inc.