U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2024-1486

Change History

CVE Modified by CISA-ADP 6/17/2026 3:04:20 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"gehealthcare","product":"venue_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"R1","status":"affected"},{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"venue_go_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"venue_fit_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"logiq_e_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"R7","lessThanOrEqual":"R9.1.4","versionType":"custom","status":"affected"},{"version":"R8","lessThanOrEqual":"R10.1.3","versionType":"custom","status":"affected"},{"version":"R9","lessThanOrEqual":"R11.0.2","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"logiq_he_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThanOrEqual":"R9.3.1","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"vivid_e_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"E95","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E90","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E80","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E9 113.2","lessThanOrEqual":"113.2","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"vivid_s_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"70N","lessThan":"206","versionType":"custom","status":"affected"},{"version":"60N","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"vivid_t_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"T8","lessThan":"206","versionType":"custom","status":"affected"},{"version":"T9","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"vivid_iq_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"gehealthcare","product":"invenia_abus_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"1.2.3","status":"affected"}]},{"vendor":"gehealthcare","product":"invenia_abus_2.0_firmware","defaultStatus":"unaffected","cpes":["cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"2.2.9","versionType":"custom","status":"affected"}]}]
Added SSVC

                  
                
              
{"timestamp":"2024-06-12T14:08:59.014421Z","id":"CVE-2024-1486","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by GE Healthcare 6/17/2026 3:04:20 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"GE HealthCare","product":"Venue","defaultStatus":"unaffected","versions":[{"version":"R1","status":"affected"},{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Venue Go","defaultStatus":"unaffected","versions":[{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Venue Fit","defaultStatus":"unaffected","versions":[{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.2","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ e","defaultStatus":"unaffected","versions":[{"version":"R7","lessThanOrEqual":"R9.1.4","versionType":"custom","status":"affected"},{"version":"R8","lessThanOrEqual":"R10.1.3","versionType":"custom","status":"affected"},{"version":"R9","lessThanOrEqual":"R11.0.2","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ He","defaultStatus":"unaffected","versions":[{"version":"0","lessThanOrEqual":"R9.3.1","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid E","defaultStatus":"unaffected","versions":[{"version":"E95","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E90","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E80","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E9 113.2","lessThanOrEqual":"113.2","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid S","defaultStatus":"unaffected","versions":[{"version":"70N","lessThan":"206","versionType":"custom","status":"affected"},{"version":"60N","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid T","defaultStatus":"unaffected","versions":[{"version":"T8","lessThan":"206","versionType":"custom","status":"affected"},{"version":"T9","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid iq","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Invenia ABUS","defaultStatus":"unaffected","versions":[{"version":"1.2.3","status":"affected"}]},{"vendor":"GE HealthCare","product":"Invenia ABUS 2.0","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"2.2.9","versionType":"custom","status":"affected"}]}]