U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2024-1628

Change History

CVE Modified by CISA-ADP 6/17/2026 3:04:39 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"ge_healthcare","product":"venue","defaultStatus":"unknown","cpes":["cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"],"versions":[{"version":"multiple versions","status":"affected"}]},{"vendor":"ge_healthcare","product":"vivid","defaultStatus":"unknown","cpes":["cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"],"versions":[{"version":"multiple versions","status":"affected"}]},{"vendor":"ge_healthcare","product":"voluson","defaultStatus":"unknown","cpes":["cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"],"versions":[{"version":"multiple versions","status":"affected"}]},{"vendor":"ge_healthcare","product":"logiq","defaultStatus":"unknown","cpes":["cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"],"versions":[{"version":"multiple versions","status":"affected"}]}]
Added SSVC

                  
                
              
{"timestamp":"2024-05-16T16:10:00.517201Z","id":"CVE-2024-1628","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by GE Healthcare 6/17/2026 3:04:39 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"GE HealthCare","product":"Venue","defaultStatus":"unaffected","versions":[{"version":"R1","status":"affected"},{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.3","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Venue Go","defaultStatus":"unaffected","versions":[{"version":"R2","status":"affected"},{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.3","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Venue Fit","defaultStatus":"unaffected","versions":[{"version":"R3","lessThanOrEqual":"R3.3","versionType":"custom","status":"affected"},{"version":"R4","lessThanOrEqual":"R4.3","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ e","defaultStatus":"unaffected","versions":[{"version":"R7","lessThanOrEqual":"R9.1.4","versionType":"custom","status":"affected"},{"version":"R8","lessThanOrEqual":"R10.1.3","versionType":"custom","status":"affected"},{"version":"R9","lessThanOrEqual":"R11.0.3","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ He","defaultStatus":"unaffected","versions":[{"version":"0","lessThanOrEqual":"R9.3.1","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid E","defaultStatus":"unaffected","versions":[{"version":"E95","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E90","lessThan":"206","versionType":"custom","status":"affected"},{"version":"E80","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid S","defaultStatus":"unaffected","versions":[{"version":"70N","lessThan":"206","versionType":"custom","status":"affected"},{"version":"60N","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid T","defaultStatus":"unaffected","versions":[{"version":"T8","lessThan":"206","versionType":"custom","status":"affected"},{"version":"T9","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Vivid iq","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"206","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Voluson Expert 16","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected"},{"version":"BT24","lessThan":"Ext1","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Voluson Expert 18","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected"},{"version":"BT24","lessThan":"Ext1","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Voluson Expert 22","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected"},{"version":"BT24","lessThan":"Ext1","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"Voluson SWIFT","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected"},{"version":"BT24","status":"affected"}]},{"vendor":"GE HealthCare","product":"Invenia ABUS 2.0","defaultStatus":"unaffected","versions":[{"version":"0","lessThanOrEqual":"2.2.7","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ E10","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"R3.2.0","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ E10s","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"R3.2.0","versionType":"custom","status":"affected"}]},{"vendor":"GE HealthCare","product":"LOGIQ Fortis","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"R3.2.0","versionType":"custom","status":"affected"}]}]