U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2024-39518

Change History

New CVE Received by NIST 7/10/2024 7:15:11 PM

Action Type Old Value New Value
Added CVSS V3.1

								
							
							
						
Juniper Networks, Inc. AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Added CVSS V4.0

								
							
							
						
Juniper Networks, Inc. CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added CWE

								
							
							
						
Juniper Networks, Inc. CWE-122
Added Description

								
							
							
						
A Heap-based Buffer Overflow vulnerability in the telemetry sensor process (sensord) of Juniper Networks Junos OS on MX240, MX480, MX960 platforms using MPC10E causes a steady increase in memory utilization, ultimately leading to a Denial of Service (DoS).

When the device is subscribed to a specific subscription on Junos Telemetry Interface, a slow memory leak occurs and eventually all resources are consumed and the device becomes unresponsive. A manual reboot of the Line Card will be required to restore the device to its normal functioning. 

This issue is only seen when telemetry subscription is active.

The Heap memory utilization can be monitored using the following command:
  > show system processes extensive

The following command can be used to monitor the memory utilization of the specific sensor
  > show system info | match sensord
   PID   NAME                 MEMORY     PEAK MEMORY    %CPU   THREAD-COUNT CORE-AFFINITY   UPTIME

   1986  sensord            877.57MB   877.57MB         2       4           0,2-15          7-21:41:32


This issue affects Junos OS: 



  *  from 21.2R3-S5 before 21.2R3-S7, 
  *  from 21.4R3-S4 before 21.4R3-S6, 
  *  from 22.2R3 before 22.2R3-S4, 
  *  from 22.3R2 before 22.3R3-S2, 
  *  from 22.4R1 before 22.4R3, 
  *  from 23.2R1 before 23.2R2.
Added Reference

								
							
							
						
Juniper Networks, Inc. https://supportportal.juniper.net/JSA82982 [No types assigned]