You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:siemens:ntermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 7.2.12
OR
cpe:2.3:h:siemens:ntermesh_7707_fire_subscriber:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:intermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 7.2.12
OR
cpe:2.3:h:siemens:intermesh_7707_fire_subscriber:-:*:*:*:*:*:*:*
Reanalysis by NIST10/30/2024 11:24:40 AM
Action
Type
Old Value
New Value
Changed
Reference Type
https://cert-portal.siemens.com/productcert/html/ssa-333468.html Third Party Advisory
AND
OR
*cpe:2.3:o:siemens:intermesh_7177_hybrid_2.0_subscriber:*:*:*:*:*:*:*:* versions up to (excluding) 8.2.12
OR
cpe:2.3:h:siemens:intermesh_7177_hybrid_2.0_subscriber:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:ntermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 7.2.12
OR
cpe:2.3:h:siemens:ntermesh_7707_fire_subscriber:-:*:*:*:*:*:*:*
Changed
Reference Type
https://cert-portal.siemens.com/productcert/html/ssa-333468.html No Types Assigned
https://cert-portal.siemens.com/productcert/html/ssa-333468.html Third Party Advisory
New CVE Received from Siemens AG10/23/2024 11:15:31 AM
Action
Type
Old Value
New Value
Added
Description
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.
Added
CVSS V4.0
Siemens AG CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added
CVSS V3.1
Siemens AG AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Added
CWE
Siemens AG CWE-266
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-333468.html [No types assigned]
Quick Info
CVE Dictionary Entry: CVE-2024-47904 NVD
Published Date: 10/23/2024 NVD
Last Modified: 10/30/2024
Source: Siemens AG