U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2024-52051

Change History

CVE Modified by CISA-ADP 6/17/2026 4:06:52 AM

Action Type Old Value New Value
Added SSVC

                  
                
              
{"timestamp":"2024-12-11T17:13:19.265210Z","id":"CVE-2024-52051","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by Siemens AG 6/17/2026 4:06:52 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 Safety V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V17 Update 9","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 Safety V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 Safety V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 4","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V17 Update 9","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC STEP 7 V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 4","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Unified PC Runtime V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Unified PC Runtime V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 4","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Unified V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V17 Update 9","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Unified V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Unified V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 4","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V17 Update 9","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 4","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOCODE ES V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOCODE ES V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOCODE ES V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.4","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.5","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.6","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V5.6 SP1 HF7","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS Startdrive V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS Startdrive V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SINAMICS Startdrive V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Safety ES V17 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Safety ES V18 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Safety ES V19 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Soft Starter ES V17 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Soft Starter ES V18 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIRIUS Soft Starter ES V19 (TIA Portal)","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"TIA Portal Cloud V17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"TIA Portal Cloud V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"TIA Portal Cloud V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V5.2.1.1","versionType":"custom","status":"affected"}]}]