U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2026-48192

Change History

New CVE Received from Siemens AG 6/30/2026 11:16:56 AM

Action Type Old Value New Value
Added Description

                  
                
              
A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions < V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions < V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.
This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.
Added CVSS V4.0

                  
                
              
AV:N/AC:H/AT:N/PR:H/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added CVSS V3.1

                  
                
              
AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N
Added CWE

                  
                
              
CWE-94
Added Reference

                  
                
              
https://cert-portal.siemens.com/productcert/html/ssa-779310.html
Added Affected

                  
                
              
[{"vendor":"Siemens","product":"Mendix Studio Pro 10.11","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.12","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.13","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.14","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.15","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.16","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.17","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.20","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.21","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.22","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.23","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 10.24","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V10.24.21","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.0","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.1","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.10","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.11","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.2","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.3","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.4","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.5","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.6","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V11.6.7","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.7","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.8","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"Mendix Studio Pro 11.9","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"*","versionType":"custom","status":"affected"}]}]