Vulnerability Change Records for CVE-2026-4827

Change History

CVE Modified by CISA-ADP 6/17/2026 6:57:17 AM

Action Type Old Value New Value
Added SSVC

                  
                
              
{"timestamp":"2026-05-12T12:39:02.210471Z","id":"CVE-2026-4827","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by Schneider Electric SE 6/17/2026 6:57:17 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"Schneider Electric","product":"Easergy MiCOM C264","defaultStatus":"unaffected","versions":[{"version":"Versions D6.x","status":"affected"},{"version":"Versions D7.33 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy C5","defaultStatus":"unaffected","versions":[{"version":"Version 1.1.17 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P30","defaultStatus":"unaffected","versions":[{"version":"P139 version prior to P139.678.700","status":"affected"},{"version":"P437 version prior to P437.678.700","status":"affected"},{"version":"P439 version prior to P439.678.700","status":"affected"},{"version":"P532 version prior to P532.678.700","status":"affected"},{"version":"P539 version prior to P539.678.700","status":"affected"},{"version":"P631 version prior to P631.678.700","status":"affected"},{"version":"P632 version prior to P632.678.700","status":"affected"},{"version":"P633 version prior to P633.678.700","status":"affected"},{"version":"P634 version prior to P634.678.700","status":"affected"},{"version":"P633 version P633.680.700 only","status":"affected"},{"version":"P634 version P634.680.700 only","status":"affected"},{"version":"P138 version prior to P138.677.700","status":"affected"},{"version":"P436 version prior to P436.677.701","status":"affected"},{"version":"P438 version prior to P438.677.701","status":"affected"},{"version":"P638 version prior to P638.677.700","status":"affected"},{"version":"C434 version prior to C434.679.700","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P40","defaultStatus":"unaffected","versions":[{"version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","defaultStatus":"unaffected","versions":[{"version":"Version 6.4.616.200.100 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","defaultStatus":"unaffected","versions":[{"version":"Version 3.0.3 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","defaultStatus":"unaffected","versions":[{"version":"Version 2022 CU6 and prior","status":"affected"},{"version":"Version 2024 CU2 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"iPMFLS","defaultStatus":"unaffected","versions":[{"version":"Version 64.2025.0.13 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P5 Protection Relay","defaultStatus":"unaffected","versions":[{"version":"V02.502.103 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P7 Protection and Control Platform","defaultStatus":"unaffected","versions":[{"version":"V02.002.002 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T300","defaultStatus":"unaffected","versions":[{"version":"Version 2.9.4 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T500","defaultStatus":"unaffected","versions":[{"version":"Version 11.08.02 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Saitel DP","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.36 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EasyLogic T150 (formerly Saitel DR)","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.30 and prior","status":"affected"}]}]