Description
A vulnerability in a logging API in Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to cause the device to become unresponsive or trigger an unexpected reload. This vulnerability could also allow an attacker with valid user credentials, but not Administrator privileges, to view a system log file that they would not normally have access to. This vulnerability is due to a lack of rate-limiting of requests that are sent to a specific API that is related to an FMC log. An attacker could exploit this vulnerability by sending a high rate of HTTP requests to the API. A successful exploit could allow the attacker to cause a denial of service (DoS) condition due to the FMC CPU spiking to 100 percent utilization or to the device reloading. CPU utilization would return to normal if the attack traffic was stopped before an unexpected reload was triggered.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
OR
*cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:* versions from (including) 6.2.3 up to (including) 6.2.3.18
*cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:* versions from (including) 6.4.0 up to (including) 6.4.0.16
*cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:* versions from (including) 6.6.0 up to (including) 6.6.7.1
*cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:* versions from (including) 7.0.0 up to (including) 7.0.5
Changed
Reference Type
https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-logview-dos-AYJdeX55 No Types Assigned