Description

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (Windows client deployments) contain an insecure temporary-file handling vulnerability in the PrinterInstallerClient components. The software creates files as NT AUTHORITY\SYSTEM inside a directory under the control of the local user (C:\Users\%USER%\AppData\Local\Temp\). An attacker who can place symbolic links or otherwise influence filenames in that directory can cause the service to follow the link and write to arbitrary filesystem locations as SYSTEM. This allows a local, unprivileged user to overwrite or create files as SYSTEM, leading to local privilege escalation and the ability to modify configuration files, replace or inject binaries, or otherwise compromise confidentiality, integrity, and availability of the system. NOTE: This vulnerability has been addressed, but an affected version range is not yet fully determined. This record will be updated when the vendor provides confirmed version information.


Metrics

NVD enrichment efforts reference publicly available information to associate vector strings. CVSS information contributed by other sources is also displayed.
CVSS 4.0 Severity and Vector Strings:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.

Nist CVSS score does not match with CNA score
CNA:  VulnCheck
CVSS-B 8.5 HIGH
Vector:  CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected].

URL Source(s) Tag(s)
https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm VulnCheck
https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm VulnCheck
https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#win-lpe-02 VulnCheck
https://www.vulncheck.com/advisories/vasion-print-printerlogic-lpe-via-insecure-temporary-file-handling VulnCheck

Weakness Enumeration

CWE-ID CWE Name Source
CWE-377 Insecure Temporary File VulnCheck  
CWE-59 Improper Link Resolution Before File Access ('Link Following') VulnCheck  