Search Results (Refine Search)
- Keyword (text search): cpe:2.3:o:siemens:scalance_xr500_firmware:-:*:*:*:*:*:*:*
- CPE Name Search: true
Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2022-36325 |
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. Published: August 10, 2022; 8:15:12 AM -0400 |
V4.0:(not available) V3.1: 4.8 MEDIUM V2.0:(not available) |
CVE-2022-36324 |
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. Published: August 10, 2022; 8:15:12 AM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0:(not available) |
CVE-2022-36323 |
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Published: August 10, 2022; 8:15:12 AM -0400 |
V4.0:(not available) V3.1: 9.1 CRITICAL V2.0:(not available) |
CVE-2020-28400 |
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Published: July 13, 2021; 7:15:08 AM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2021-25667 |
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. Published: March 15, 2021; 1:15:21 PM -0400 |
V4.0:(not available) V3.1: 8.8 HIGH V2.0: 5.8 MEDIUM |
CVE-2017-2681 |
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. Published: May 11, 2017; 6:29:00 AM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 6.1 MEDIUM |
CVE-2017-2680 |
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Published: May 10, 2017; 9:29:05 PM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 6.1 MEDIUM |