Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2021-37199 |
A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device. Published: October 12, 2021; 6:15:12 AM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 7.8 HIGH |
CVE-2018-11464 |
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. Published: December 12, 2018; 11:29:00 AM -0500 |
V4.0:(not available) V3.0: 3.7 LOW V2.0: 4.3 MEDIUM |
CVE-2017-2681 |
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. Published: May 11, 2017; 6:29:00 AM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 6.1 MEDIUM |
CVE-2017-2680 |
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Published: May 10, 2017; 9:29:05 PM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 6.1 MEDIUM |