Search Results (Refine Search)

Search Parameters:
  • Keyword (text search): cpe:2.3:o:juniper:junos:16.1:r7-s4:*:*:*:*:*:*
There are 61 matching records.
Displaying matches 1 through 20.
Vuln ID Summary CVSS Severity
CVE-2021-0222

A vulnerability in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) to the device by sending certain crafted protocol packets from an adjacent device with invalid payloads to the device. These crafted packets, which should be discarded, are instead replicated and sent to the RE. Over time, a Denial of Service (DoS) occurs. Continued receipt of these crafted protocol packets will cause an extended Denial of Service (DoS) condition, which may cause wider traffic impact due to protocol flapping. An indication of compromise is to check "monitor interface traffic" on the ingress and egress port packet counts. For each ingress packet, two duplicate packets are seen on egress. This issue can be triggered by IPv4 and IPv6 packets. This issue affects all traffic through the device. This issue affects: Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300, QFX3500, QFX5100, EX4600; 15.1 versions prior to 15.1R7-S6 on EX4300, QFX3500, QFX5100, EX4600; 16.1 versions prior to 16.1R7-S7 on EX4300, QFX5100, EX4600; 17.1 versions prior to 17.1R2-S11 on EX4300, QFX5100, EX4600; 17.1 versions prior to 117.1R3-S2 on EX4300; 17.2 versions prior to 17.2R1-S9 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 18.1 versions prior to 18.1R3-S9 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, EX2300, EX3400; 18.2 versions prior to 18.2R2-S7 on EX4300; 18.2 versions prior to 18.2R3-S3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, EX2300, EX3400; 18.3 versions prior to 18.3R2-S3, on EX4300; 18.3 versions prior to 18.3R1-S7, 18.3R3-S1 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.2 versions prior to 19.2R1-S3, 19.2R2 on QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.3 versions prior to 19.3R2-S1, 19.3R3 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2, 19.3R3 on QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400;

Published: January 15, 2021; 1:15:15 PM -0500
V3.1: 7.4 HIGH
V2.0: 6.1 MEDIUM
CVE-2021-0215

On Juniper Networks Junos EX series, QFX Series, MX Series and SRX branch series devices, a memory leak occurs every time the 802.1X authenticator port interface flaps which can lead to other processes, such as the pfex process, responsible for packet forwarding, to crash and restart. An administrator can use the following CLI command to monitor the status of memory consumption: user@device> show task memory detail Please refer to https://kb.juniper.net/KB31522 for details. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D54; 15.1X49 versions prior to 15.1X49-D240 ; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10 ; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. This issue does not affect Juniper Networks Junos OS 12.3, 15.1.

Published: January 15, 2021; 1:15:15 PM -0500
V3.1: 6.5 MEDIUM
V2.0: 2.9 LOW
CVE-2021-0203

On Juniper Networks EX and QFX5K Series platforms configured with Redundant Trunk Group (RTG), Storm Control profile applied on the RTG interface might not take affect when it reaches the threshold condition. Storm Control enables the device to monitor traffic levels and to drop broadcast, multicast, and unknown unicast packets when a specified traffic level is exceeded, thus preventing packets from proliferating and degrading the LAN. Note: this issue does not affect EX2200, EX3300, EX4200, and EX9200 Series. This issue affects Juniper Networks Junos OS on EX Series and QFX5K Series: 15.1 versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R2-S5, 18.4R3-S3; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R2-S1, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2.

Published: January 15, 2021; 1:15:14 PM -0500
V3.1: 8.6 HIGH
V2.0: 4.3 MEDIUM
CVE-2020-1688

On Juniper Networks SRX Series and NFX Series, a local authenticated user with access to the shell may obtain the Web API service private key that is used to provide encrypted communication between the Juniper device and the authenticator services. Exploitation of this vulnerability may allow an attacker to decrypt the communications between the Juniper device and the authenticator service. This Web API service is used for authentication services such as the Juniper Identity Management Service, used to obtain user identity for Integrated User Firewall feature, or the integrated ClearPass authentication and enforcement feature. This issue affects Juniper Networks Junos OS on Networks SRX Series and NFX Series: 12.3X48 versions prior to 12.3X48-D105; 15.1X49 versions prior to 15.1X49-D190; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R1-S7, 18.4R2; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S4, 19.2R2.

Published: October 16, 2020; 5:15:14 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 2.1 LOW
CVE-2020-1680

On Juniper Networks MX Series with MS-MIC or MS-MPC card configured with NAT64 configuration, receipt of a malformed IPv6 packet may crash the MS-PIC component on MS-MIC or MS-MPC. This issue occurs when a multiservice card is translating the malformed IPv6 packet to IPv4 packet. An unauthenticated attacker can continuously send crafted IPv6 packets through the device causing repetitive MS-PIC process crashes, resulting in an extended Denial of Service condition. This issue affects Juniper Networks Junos OS on MX Series: 15.1 versions prior to 15.1R7-S7; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S11, 17.4R3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D53, 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2.

Published: October 16, 2020; 5:15:13 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2020-1661

On Juniper Networks Junos OS devices configured as a DHCP forwarder, the Juniper Networks Dynamic Host Configuration Protocol Daemon (jdhcp) process might crash when receiving a malformed DHCP packet. This issue only affects devices configured as DHCP forwarder with forward-only option, that forward specified DHCP client packets, without creating a new subscriber session. The jdhcpd daemon automatically restarts without intervention, but continuous receipt of the malformed DHCP packet will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue can be triggered only by DHCPv4, it cannot be triggered by DHCPv6. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 14.1X53 versions prior to 14.1X53-D60 on EX and QFX Series; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230 on SRX Series; 15.1X53 versions prior to 15.1X53-D593 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S5.

Published: October 16, 2020; 5:15:12 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2020-1656

The DHCPv6 Relay-Agent service, part of the Juniper Enhanced jdhcpd daemon shipped with Juniper Networks Junos OS has an Improper Input Validation vulnerability which will result in a Denial of Service (DoS) condition when a DHCPv6 client sends a specific DHPCv6 message allowing an attacker to potentially perform a Remote Code Execution (RCE) attack on the target device. Continuous receipt of the specific DHCPv6 client message will result in an extended Denial of Service (DoS) condition. If adjacent devices are also configured to relay DHCP packets, and are not affected by this issue and simply transparently forward unprocessed client DHCPv6 messages, then the attack vector can be a Network-based attack, instead of an Adjacent-device attack. No other DHCP services are affected. Receipt of the packet without configuration of the DHCPv6 Relay-Agent service, will not result in exploitability of this issue. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95; 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D44; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R2-S6, 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D435, 18.2X75-D60; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S4, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2.

Published: October 16, 2020; 5:15:12 PM -0400
V3.1: 8.8 HIGH
V2.0: 5.8 MEDIUM
CVE-2020-1643

Execution of the "show ospf interface extensive" or "show ospf interface detail" CLI commands on a Juniper Networks device running Junos OS may cause the routing protocols process (RPD) to crash and restart if OSPF interface authentication is configured, leading to a Denial of Service (DoS). By continuously executing the same CLI commands, a local attacker can repeatedly crash the RPD process causing a sustained Denial of Service. Note: Only systems utilizing ARM processors, found on the EX2300 and EX3400, are vulnerable to this issue. Systems shipped with other processor architectures are not vulnerable to this issue. The processor architecture can be displayed via the 'uname -a' command. For example: ARM (vulnerable): % uname -a | awk '{print $NF}' arm PowerPC (not vulnerable): % uname -a | awk '{print $NF}' powerpc AMD (not vulnerable): % uname -a | awk '{print $NF}' amd64 Intel (not vulnerable): % uname -a | awk '{print $NF}' i386 This issue affects Juniper Networks Junos OS: 12.3X48 versions prior to 12.3X48-D100; 14.1X53 versions prior to 14.1X53-D140, 14.1X53-D54; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D210; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2, 18.2R3; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2.

Published: July 17, 2020; 3:15:12 PM -0400
V3.1: 5.5 MEDIUM
V2.0: 1.9 LOW
CVE-2020-1641

A Race Condition vulnerability in Juniper Networks Junos OS LLDP implementation allows an attacker to cause LLDP to crash leading to a Denial of Service (DoS). This issue occurs when crafted LLDP packets are received by the device from an adjacent device. Multiple LACP flaps will occur after LLDP crashes. An indicator of compromise is to evaluate log file details for lldp with RLIMIT. Intervention should occur before 85% threshold of used KB versus maximum available KB memory is reached. show log messages | match RLIMIT | match lldp | last 20 Matching statement is " /kernel: %KERNEL-[number]: Process ([pid #],lldpd) has exceeded 85% of RLIMIT_DATA: " with [] as variable data to evaluate for. This issue affects: Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S4, 17.4R3; 18.1 versions prior to 18.1R3-S5; 18.2 versions prior to 18.2R2-S7, 18.2R3; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D50, 18.2X75-D420; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2.

Published: July 17, 2020; 3:15:12 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 2.9 LOW
CVE-2020-1631

A vulnerability in the HTTP/HTTPS service used by J-Web, Web Authentication, Dynamic-VPN (DVPN), Firewall Authentication Pass-Through with Web-Redirect, and Zero Touch Provisioning (ZTP) allows an unauthenticated attacker to perform local file inclusion (LFI) or path traversal. Using this vulnerability, an attacker may be able to inject commands into the httpd.log, read files with 'world' readable permission file or obtain J-Web session tokens. In the case of command injection, as the HTTP service runs as user 'nobody', the impact of this command injection is limited. (CVSS score 5.3, vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N) In the case of reading files with 'world' readable permission, in Junos OS 19.3R1 and above, the unauthenticated attacker would be able to read the configuration file. (CVSS score 5.9, vector CVSS:3.1/ AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N) If J-Web is enabled, the attacker could gain the same level of access of anyone actively logged into J-Web. If an administrator is logged in, the attacker could gain administrator access to J-Web. (CVSS score 8.8, vector CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) This issue only affects Juniper Networks Junos OS devices with HTTP/HTTPS services enabled. Junos OS devices with HTTP/HTTPS services disabled are not affected. If HTTP/HTTPS services are enabled, the following command will show the httpd processes: user@device> show system processes | match http 5260 - S 0:00.13 /usr/sbin/httpd-gk -N 5797 - I 0:00.10 /usr/sbin/httpd --config /jail/var/etc/httpd.conf To summarize: If HTTP/HTTPS services are disabled, there is no impact from this vulnerability. If HTTP/HTTPS services are enabled and J-Web is not in use, this vulnerability has a CVSS score of 5.9 (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). If J-Web is enabled, this vulnerability has a CVSS score of 8.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Juniper SIRT has received a single report of this vulnerability being exploited in the wild. Out of an abundance of caution, we are notifying customers so they can take appropriate actions. Indicators of Compromise: The /var/log/httpd.log may have indicators that commands have injected or files being accessed. The device administrator can look for these indicators by searching for the string patterns "=*;*&" or "*%3b*&" in /var/log/httpd.log, using the following command: user@device> show log httpd.log | match "=*;*&|=*%3b*&" If this command returns any output, it might be an indication of malicious attempts or simply scanning activities. Rotated logs should also be reviewed, using the following command: user@device> show log httpd.log.0.gz | match "=*;*&|=*%3b*&" user@device> show log httpd.log.1.gz | match "=*;*&|=*%3b*&" Note that a skilled attacker would likely remove these entries from the local log file, thus effectively eliminating any reliable signature that the device had been attacked. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D101, 12.3X48-D105; 14.1X53 versions prior to 14.1X53-D54; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D211, 15.1X49-D220; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R3-S2 ; 18.4 version 18.4R2 and later versions; 19.1 versions prior to 19.1R1-S5, 19.1R3-S1; 19.1 version 19.1R2 and later versions; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2; 20.1 versions prior to 20.1R1-S1, 20.1R2.

Published: May 04, 2020; 6:15:10 AM -0400
V3.1: 9.8 CRITICAL
V2.0: 6.8 MEDIUM
CVE-2020-1632

In a certain condition, receipt of a specific BGP UPDATE message might cause Juniper Networks Junos OS and Junos OS Evolved devices to advertise an invalid BGP UPDATE message to other peers, causing the other peers to terminate the established BGP session, creating a Denial of Service (DoS) condition. For example, Router A sends a specific BGP UPDATE to Router B, causing Router B to send an invalid BGP UPDATE message to Router C, resulting in termination of the BGP session between Router B and Router C. This issue might occur when there is at least a single BGP session established on the device that does not support 4 Byte AS extension (RFC 4893). Repeated receipt of the same BGP UPDATE can result in an extended DoS condition. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R1-S9, 17.2R2-S8, 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D105, 17.2X75-D110, 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2-S6, 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R3; 18.4 version 18.4R2 and later versions; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS prior to 16.1R1. This issue affects Juniper Networks Junos OS Evolved prior to 19.2R2-EVO.

Published: April 15, 2020; 5:15:35 PM -0400
V3.1: 8.6 HIGH
V2.0: 7.8 HIGH
CVE-2020-1629

A race condition vulnerability on Juniper Network Junos OS devices may cause the routing protocol daemon (RPD) process to crash and restart while processing a BGP NOTIFICATION message. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.2 version 17.2R2 and later versions; 17.2X75 versions prior to 17.2X75-D105, 17.2X75-D110; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S3; 18.2X75 versions prior to 18.2X75-D410, 18.2X75-D420, 18.2X75-D50, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S2, 19.1R2; 19.2 versions prior to 19.2R1-S4, 19.2R2. This issue does not affect Juniper Networks Junos OS prior to version 16.1R1.

Published: April 08, 2020; 4:15:14 PM -0400
V3.1: 5.9 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2020-1628

Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an EX4300 switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300; 15.1 versions prior to 15.1R7-S6 on EX4300; 15.1X49 versions prior to 15.1X49-D200, 15.1X49-D210 on EX4300; 16.1 versions prior to 16.1R7-S7 on EX4300; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300; 18.1 versions prior to 18.1R3-S8 on EX4300; 18.2 versions prior to 18.2R3-S2 on EX4300; 18.3 versions prior to 18.3R2-S3, 18.3R3, 18.3R3-S1 on EX4300; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300; 19.1 versions prior to 19.1R1-S4, 19.1R2 on EX4300; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2 on EX4300.

Published: April 08, 2020; 4:15:14 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2020-1625

The kernel memory usage represented as "temp" via 'show system virtual-memory' may constantly increase when Integrated Routing and Bridging (IRB) is configured with multiple underlay physical interfaces, and one interface flaps. This memory leak can affect running daemons (processes), leading to an extended Denial of Service (DoS) condition. Usage of "temp" virtual memory, shown here by a constantly increasing value of outstanding Requests, can be monitored by executing the 'show system virtual-memory' command as shown below: user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 10551 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6460 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 16101 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6665 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 21867 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6858 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S5, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2. This issue does not affect Juniper Networks Junos OS 12.3 and 15.1.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 3.3 LOW
CVE-2020-1619

A privilege escalation vulnerability in Juniper Networks QFX10K Series, EX9200 Series, MX Series, and PTX Series with Next-Generation Routing Engine (NG-RE), allows a local authenticated high privileged user to access the underlying WRL host. This issue only affects QFX10K Series with NG-RE, EX9200 Series with NG-RE, MX Series with NG-RE and PTX Series with NG-RE; which uses vmhost. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S4; 18.2 versions prior to 18.2R3; 18.2X75 versions prior to 18.2X75-D50; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2. To identify whether the device has NG-RE with vmhost, customer can run the following command: > show vmhost status Compute cluster: rainier-re-cc Compute Node: rainier-re-cn, Online If the "show vmhost status" is not supported, then the device does not have NG-RE with vmhost.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 6.7 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2020-1614

A Use of Hard-coded Credentials vulnerability exists in the NFX250 Series for the vSRX Virtual Network Function (VNF) instance, which allows an attacker to take control of the vSRX VNF instance if they have the ability to access an administrative service (e.g. SSH) on the VNF, either locally, or through the network. This issue only affects the NFX250 Series vSRX VNF. No other products or platforms are affected. This issue is only applicable to environments where the vSRX VNF root password has not been configured. This issue affects the Juniper Networks NFX250 Network Services Platform vSRX VNF instance on versions prior to 19.2R1.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 10.0 CRITICAL
V2.0: 9.3 HIGH
CVE-2020-1613

A vulnerability in the BGP FlowSpec implementation may cause a Juniper Networks Junos OS device to terminate an established BGP session upon receiving a specific BGP FlowSpec advertisement. The BGP NOTIFICATION message that terminates an established BGP session is sent toward the peer device that originally sent the specific BGP FlowSpec advertisement. This specific BGP FlowSpec advertisement received from a BGP peer might get propagated from a Junos OS device running the fixed release to another device that is vulnerable causing BGP session termination downstream. This issue affects IPv4 and IPv6 BGP FlowSpec deployment. This issue affects Juniper Networks Junos OS: 12.3; 12.3X48 on SRX Series; 14.1X53 on EX and QFX Series; 15.1 versions prior to 15.1R7-S5; 15.1F versions prior to 15.1F6-S13; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D497 on NFX Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3; 17.2 versions prior to 17.2R2-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110, 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R1-S8, 17.4R2; 18.1 versions prior to 18.1R2-S4, 18.1R3; 18.2X75 versions prior to 18.2X75-D20.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2020-1609

When a device using Juniper Network's Dynamic Host Configuration Protocol Daemon (JDHCPD) process on Junos OS or Junos OS Evolved which is configured in relay mode it vulnerable to an attacker sending crafted IPv6 packets who may then arbitrarily execute commands as root on the target device. This issue affects IPv6 JDHCPD services. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2*. and All versions prior to 19.3R1 on Junos OS Evolved. This issue do not affect versions of Junos OS prior to 15.1, or JDHCPD operating as a local server in non-relay mode.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.8 HIGH
V2.0: 8.3 HIGH
CVE-2020-1607

Insufficient Cross-Site Scripting (XSS) protection in J-Web may potentially allow a remote attacker to inject web script or HTML, hijack the target user's J-Web session and perform administrative actions on the Junos device as the targeted user. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90 on SRX Series; 14.1X53 versions prior to 14.1X53-D51 on EX and QFX Series; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.3 versions prior to 18.3R1-S6, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S2, 19.1R2.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2020-1606

A path traversal vulnerability in the Juniper Networks Junos OS device may allow an authenticated J-web user to read files with 'world' readable permission and delete files with 'world' writeable permission. This issue does not affect system files that can be accessed only by root user. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S13; 12.3X48 versions prior to 12.3X48-D85 on SRX Series; 14.1X53 versions prior to 14.1X53-D51; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.1 HIGH
V2.0: 6.5 MEDIUM