Search Parameters:
  • CPE Product Version: cpe:/a:siemens:simatic_pcs7:8.0
There are 23 matching records.
Displaying matches 1 through 20.
Vuln ID Summary CVSS Severity
CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.

Published: August 30, 2017; 3:29:00 PM -0400
V3.0: 8.2 HIGH
V2.0: 6.4 MEDIUM
CVE-2016-7165

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).

Published: November 15, 2016; 2:30:02 PM -0500
V3.0: 6.4 MEDIUM
V2.0: 6.9 MEDIUM
CVE-2014-8552

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.

Published: November 26, 2014; 6:59:01 AM -0500
V3.x:(not available)
V2.0: 5.0 MEDIUM
CVE-2014-8551

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.

Published: November 26, 2014; 6:59:00 AM -0500
V3.x:(not available)
V2.0: 10.0 HIGH
CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.

Published: July 24, 2014; 10:55:08 AM -0400
V3.x:(not available)
V2.0: 6.8 MEDIUM
CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.

Published: July 24, 2014; 10:55:08 AM -0400
V3.x:(not available)
V2.0: 4.6 MEDIUM
CVE-2014-4684

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.

Published: July 24, 2014; 10:55:08 AM -0400
V3.x:(not available)
V2.0: 6.0 MEDIUM
CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.

Published: July 24, 2014; 10:55:08 AM -0400
V3.x:(not available)
V2.0: 4.9 MEDIUM
CVE-2014-4682

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.

Published: July 24, 2014; 10:55:08 AM -0400
V3.x:(not available)
V2.0: 5.0 MEDIUM
CVE-2013-3959

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.

Published: June 14, 2013; 3:55:01 PM -0400
V3.x:(not available)
V2.0: 4.0 MEDIUM
CVE-2013-3958

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.

Published: June 14, 2013; 3:55:01 PM -0400
V3.x:(not available)
V2.0: 7.5 HIGH
CVE-2013-3957

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

Published: June 14, 2013; 3:55:01 PM -0400
V3.x:(not available)
V2.0: 7.5 HIGH
CVE-2013-0679

Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 4.0 MEDIUM
CVE-2013-0678

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 4.0 MEDIUM
CVE-2013-0677

The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 5.8 MEDIUM
CVE-2013-0676

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 4.0 MEDIUM
CVE-2013-0675

Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 6.1 MEDIUM
CVE-2013-0674

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

Published: March 21, 2013; 11:55:01 AM -0400
V3.x:(not available)
V2.0: 6.8 MEDIUM
CVE-2012-3034

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.

Published: September 18, 2012; 10:55:01 AM -0400
V3.x:(not available)
V2.0: 4.3 MEDIUM
CVE-2012-3032

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

Published: September 18, 2012; 10:55:01 AM -0400
V3.x:(not available)
V2.0: 7.5 HIGH