U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
  • Keyword (text search): cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*
  • CPE Name Search: true
There are 12 matching records.
Displaying matches 1 through 12.
Vuln ID Summary CVSS Severity
CVE-2024-2855

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 24, 2024; 2:15:11 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2852

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 24, 2024; 1:15:09 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2812

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 3:15:46 AM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0:(not available)
CVE-2024-2810

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 2:15:10 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2809

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 2:15:08 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2808

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 1:15:49 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2807

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 1:15:48 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-2806

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: March 22, 2024; 1:15:48 AM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2023-39673

Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().

Published: August 17, 2023; 11:15:24 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-28557

There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution

Published: May 04, 2022; 12:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2022-28556

Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971

Published: May 04, 2022; 12:15:08 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2021-44971

Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.

Published: January 28, 2022; 2:15:07 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH