CVE-2024-0993

A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: January 28, 2024; 9:15:07 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-0992

A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: January 28, 2024; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-0991

A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: January 28, 2024; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2024-0990

A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Published: January 28, 2024; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2023-48964

Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet.

Published: November 30, 2023; 9:15:11 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2023-48963

Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget.

Published: November 30, 2023; 9:15:11 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)