Vuln ID Summary CVSS Severity
CVE-2022-22202

An Improper Handling of Exceptional Conditions vulnerability on specific PTX Series devices, including the PTX1000, PTX3000 (NextGen), PTX5000, PTX10002-60C, PTX10008, and PTX10016 Series, in Juniper Networks Junos OS allows an unauthenticated MPLS-based attacker to cause a Denial of Service (DoS) by triggering the dcpfe process to crash and FPC to restart. On affected PTX Series devices, processing specific MPLS packets received on an interface with multiple units configured may cause FPC to restart unexpectedly. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects PTX Series devices utilizing specific FPCs found on PTX1000, PTX3000 (NextGen), PTX5000, PTX10002-60C, PTX10008, and PTX10016 Series devices, only if multiple units are configured on the ingress interface, and at least one unit has 'family mpls' *not* configured. See the configuration sample below for more information. No other platforms are affected by this vulnerability. This issue affects: Juniper Networks Junos OS on PTX Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S2; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2; 22.1 versions prior to 22.1R2.

Published: July 20, 2022; 11:15:08 AM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0:(not available)
CVE-2022-22186

Due to an Improper Initialization vulnerability in Juniper Networks Junos OS on EX4650 devices, packets received on the management interface (em0) but not destined to the device, may be improperly forwarded to an egress interface, instead of being discarded. Such traffic being sent by a client may appear genuine, but is non-standard in nature and should be considered as potentially malicious. This issue affects: Juniper Networks Junos OS on EX4650 Series: All versions prior to 19.1R3-S8; 19.2 versions prior to 19.2R3-S5; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2; 22.1 versions prior to 22.1R1.

Published: April 14, 2022; 12:15:07 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 6.4 MEDIUM
CVE-2022-22181

A reflected Cross-site Scripting (XSS) vulnerability in J-Web of Juniper Networks Junos OS allows a network-based authenticated attacker to run malicious scripts reflected off J-Web to the victim's browser in the context of their session within J-Web. This may allow the attacker to gain control of the device or attack other authenticated user sessions. This issue affects: Juniper Networks Junos OS All versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.

Published: April 14, 2022; 12:15:07 PM -0400
V4.0:(not available)
V3.1: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2021-25220

BIND 9.11.0 -> 9.11.36 9.12.0 -> 9.16.26 9.17.0 -> 9.18.0 BIND Supported Preview Editions: 9.11.4-S1 -> 9.11.36-S1 9.16.8-S1 -> 9.16.26-S1 Versions of BIND 9 earlier than those shown - back to 9.1.0, including Supported Preview Editions - are also believed to be affected but have not been tested as they are EOL. The cache could become poisoned with incorrect records leading to queries being made to the wrong servers, which might also result in false information being returned to clients.

Published: March 23, 2022; 9:15:07 AM -0400
V4.0:(not available)
V3.1: 6.8 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2022-22173

A Missing Release of Memory after Effective Lifetime vulnerability in the Public Key Infrastructure daemon (pkid) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause Denial of Service (DoS). In a scenario where Public Key Infrastructure (PKI) is used in combination with Certificate Revocation List (CRL), if the CRL fails to download the memory allocated to store the CRL is not released. Repeated occurrences will eventually consume all available memory and lead to an inoperable state of the affected system causing a DoS. This issue affects Juniper Networks Junos OS: All versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S5; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. This issue can be observed by monitoring the memory utilization of the pkid process via: root@jtac-srx1500-r2003> show system processes extensive | match pki 20931 root 20 0 733M 14352K select 0:00 0.00% pkid which increases over time: root@jtac-srx1500-r2003> show system processes extensive | match pki 22587 root 20 0 901M 181M select 0:03 0.00% pkid

Published: January 18, 2022; 8:15:09 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2022-22168

An Improper Validation of Specified Type of Input vulnerability in the kernel of Juniper Networks Junos OS allows an unauthenticated adjacent attacker to trigger a Missing Release of Memory after Effective Lifetime vulnerability. Continued exploitation of this vulnerability will eventually lead to an FPC reboot and thereby a Denial of Service (DoS). This issue affects: Juniper Networks Junos OS on vMX and MX150: All versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2.

Published: January 18, 2022; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 6.1 MEDIUM
CVE-2022-22160

An Unchecked Error Condition vulnerability in the subscriber management daemon (smgd) of Juniper Networks Junos OS allows an unauthenticated adjacent attacker to cause a crash of and thereby a Denial of Service (DoS). In a subscriber management / broadband edge environment if a single session group configuration contains dual-stack and a pp0 interface, smgd will crash and restart every time a PPPoE client sends a specific message. This issue affects Juniper Networks Junos OS on MX Series: 16.1 version 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: January 18, 2022; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 2.9 LOW
CVE-2022-22156

An Improper Certificate Validation weakness in the Juniper Networks Junos OS allows an attacker to perform Person-in-the-Middle (PitM) attacks when a system script is fetched from a remote source at a specified HTTPS URL, which may compromise the integrity and confidentiality of the device. The following command can be executed by an administrator via the CLI to refresh a script from a remote location, which is affected from this vulnerability: >request system scripts refresh-from (commit | event | extension-service | op | snmp) file filename url <https-url> This issue affects: Juniper Networks Junos OS All versions prior to 18.4R2-S9, 18.4R3-S9; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R3; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R2; 21.1 versions prior to 21.1R1-S1, 21.1R2.

Published: January 18, 2022; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 7.4 HIGH
V2.0: 5.8 MEDIUM
CVE-2022-22154

In a Junos Fusion scenario an External Control of Critical State Data vulnerability in the Satellite Device (SD) control state machine of Juniper Networks Junos OS allows an attacker who is able to make physical changes to the cabling of the device to cause a denial of service (DoS). An SD can get rebooted and subsequently controlled by an Aggregation Device (AD) which does not belong to the original Fusion setup and is just connected to an extended port of the SD. To carry out this attack the attacker needs to have physical access to the cabling between the SD and the original AD. This issue affects: Juniper Networks Junos OS 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: January 18, 2022; 8:15:08 PM -0500
V4.0:(not available)
V3.1: 6.8 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2021-31382

On PTX1000 System, PTX10002-60C System, after upgrading to an affected release, a Race Condition vulnerability between the chassis daemon (chassisd) and firewall process (dfwd) of Juniper Networks Junos OS, may update the device's interfaces with incorrect firewall filters. This issue only occurs when upgrading the device to an affected version of Junos OS. Interfaces intended to have protections may have no protections assigned to them. Interfaces with one type of protection pattern may have alternate protections assigned to them. Interfaces intended to have no protections may have protections assigned to them. These firewall rule misassignments may allow genuine traffic intended to be stopped at the interface to propagate further, potentially causing disruptions in services by propagating unwanted traffic. An attacker may be able to take advantage of these misassignments. This issue affects Juniper Networks Junos OS on PTX1000 System: 17.2 versions 17.2R1 and later versions prior to 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R2-S4, 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R1-S1, 20.4R2. This issue does not affect Juniper Networks Junos OS prior to version 17.2R1 on PTX1000 System. This issue affects Juniper Networks Junos OS on PTX10002-60C System: 18.2 versions 18.2R1 and later versions prior to 18.4 versions prior to 18.4R3-S9; 19.1 versions later than 19.1R1 prior to 19.4 versions prior to 19.4R2-S5, 19.4R3-S5; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions 20.4R1 and later versions prior to 21.1 versions prior to 21.1R2; 21.2 versions 21.2R1 and later versions prior to 21.3 versions prior to 21.3R2. This issue does not affect Juniper Networks Junos OS prior to version 18.2R1 on PTX10002-60C System. This issue impacts all filter families (inet, inet6, etc.) and all loopback filters. It does not rely upon the location where a filter is set, impacting both logical and physical interfaces.

Published: October 19, 2021; 3:15:11 PM -0400
V4.0:(not available)
V3.1: 9.0 CRITICAL
V2.0: 6.8 MEDIUM
CVE-2021-31365

An Uncontrolled Resource Consumption vulnerability in Juniper Networks Junos OS on EX2300, EX3400 and EX4300 Series platforms allows an adjacent attacker sending a stream of layer 2 frames will trigger an Aggregated Ethernet (AE) interface to go down and thereby causing a Denial of Service (DoS). By continuously sending a stream of specific layer 2 frames an attacker will sustain the Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS EX4300 Series All versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS EX3400 and EX4300-MP Series All versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S9, 18.4R3-S7; 19.1 versions prior to 19.1R2-S3, 19.1R3-S4; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3; 20.3 versions prior to 20.3R2. Juniper Networks Junos OS EX2300 Series All versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.1 versions prior to 19.1R2-S3, 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R2.

Published: October 19, 2021; 3:15:09 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 2.9 LOW
CVE-2021-0289

When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.

Published: July 15, 2021; 4:15:10 PM -0400
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 2.9 LOW
CVE-2021-0248

This issue is not applicable to NFX NextGen Software. On NFX Series devices the use of Hard-coded Credentials in Juniper Networks Junos OS allows an attacker to take over any instance of an NFX deployment. This issue is only exploitable through administrative interfaces. This issue affects: Juniper Networks Junos OS versions prior to 19.1R1 on NFX Series. No other platforms besides NFX Series devices are affected.

Published: April 22, 2021; 4:15:09 PM -0400
V4.0:(not available)
V3.1: 10.0 CRITICAL
V2.0: 7.5 HIGH
CVE-2020-1671

On Juniper Networks Junos OS platforms configured as DHCPv6 local server or DHCPv6 Relay Agent, Juniper Networks Dynamic Host Configuration Protocol Daemon (JDHCPD) process might crash with a core dump if a malformed DHCPv6 packet is received, resulting with the restart of the daemon. This issue only affects DHCPv6, it does not affect DHCPv4. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.2 version 19.2R2 and later versions; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2; This issue does not affect Juniper Networks Junos OS prior to 17.4R1.

Published: October 16, 2020; 5:15:13 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2020-1653

On Juniper Networks Junos OS devices, a stream of TCP packets sent to the Routing Engine (RE) may cause mbuf leak which can lead to Flexible PIC Concentrator (FPC) crash or the system to crash and restart (vmcore). This issue can be trigged by IPv4 or IPv6 and it is caused only by TCP packets. This issue is not related to any specific configuration and it affects Junos OS releases starting from 17.4R1. However, this issue does not affect Junos OS releases prior to 18.2R1 when Nonstop active routing (NSR) is configured [edit routing-options nonstop-routing]. The number of mbufs is platform dependent. The following command provides the number of mbufs counter that are currently in use and maximum number of mbufs that can be allocated on a platform: user@host> show system buffers 2437/3143/5580 mbufs in use (current/cache/total) Once the device runs out of mbufs, the FPC crashes or the vmcore occurs and the device might become inaccessible requiring a manual restart. This issue affects Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S5; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D420.12, 18.2X75-D51, 18.2X75-D60, 18.2X75-D34; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Versions of Junos OS prior to 17.4R1 are unaffected by this vulnerability.

Published: July 17, 2020; 3:15:13 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2020-1648

On Juniper Networks Junos OS and Junos OS Evolved devices, processing a specific BGP packet can lead to a routing process daemon (RPD) crash and restart. This issue can occur even before the BGP session with the peer is established. Repeated receipt of this specific BGP packet can result in an extended Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS: 18.2X75 versions starting from 18.2X75-D50.8, 18.2X75-D60 and later versions, prior to 18.2X75-D52.8, 18.2X75-D53, 18.2X75-D60.2, 18.2X75-D65.1, 18.2X75-D70; 19.4 versions 19.4R1 and 19.4R1-S1; 20.1 versions prior to 20.1R1-S2, 20.1R2. Juniper Networks Junos OS Evolved: 19.4-EVO versions prior to 19.4R2-S2-EVO; 20.1-EVO versions prior to 20.1R2-EVO. This issue does not affect: Juniper Networks Junos OS releases prior to 19.4R1. Juniper Networks Junos OS Evolved releases prior to 19.4R1-EVO.

Published: July 17, 2020; 3:15:13 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2020-1643

Execution of the "show ospf interface extensive" or "show ospf interface detail" CLI commands on a Juniper Networks device running Junos OS may cause the routing protocols process (RPD) to crash and restart if OSPF interface authentication is configured, leading to a Denial of Service (DoS). By continuously executing the same CLI commands, a local attacker can repeatedly crash the RPD process causing a sustained Denial of Service. Note: Only systems utilizing ARM processors, found on the EX2300 and EX3400, are vulnerable to this issue. Systems shipped with other processor architectures are not vulnerable to this issue. The processor architecture can be displayed via the 'uname -a' command. For example: ARM (vulnerable): % uname -a | awk '{print $NF}' arm PowerPC (not vulnerable): % uname -a | awk '{print $NF}' powerpc AMD (not vulnerable): % uname -a | awk '{print $NF}' amd64 Intel (not vulnerable): % uname -a | awk '{print $NF}' i386 This issue affects Juniper Networks Junos OS: 12.3X48 versions prior to 12.3X48-D100; 14.1X53 versions prior to 14.1X53-D140, 14.1X53-D54; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D210; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2, 18.2R3; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2.

Published: July 17, 2020; 3:15:12 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0: 1.9 LOW
CVE-2020-1633

Due to a new NDP proxy feature for EVPN leaf nodes introduced in Junos OS 17.4, crafted NDPv6 packets could transit a Junos device configured as a Broadband Network Gateway (BNG) and reach the EVPN leaf node, causing a stale MAC address entry. This could cause legitimate traffic to be discarded, leading to a Denial of Service (DoS) condition. This issue only affects Junos OS 17.4 and later releases. Prior releases do not support this feature and are unaffected by this vulnerability. This issue only affects IPv6. IPv4 ARP proxy is unaffected by this vulnerability. This issue affects Juniper Networks Junos OS: 17.4 versions prior to 17.4R2-S9, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S9 on MX Series; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3 on MX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S2, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series.

Published: April 09, 2020; 7:15:12 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 3.3 LOW
CVE-2020-1629

A race condition vulnerability on Juniper Network Junos OS devices may cause the routing protocol daemon (RPD) process to crash and restart while processing a BGP NOTIFICATION message. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.2 version 17.2R2 and later versions; 17.2X75 versions prior to 17.2X75-D105, 17.2X75-D110; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S3; 18.2X75 versions prior to 18.2X75-D410, 18.2X75-D420, 18.2X75-D50, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S2, 19.1R2; 19.2 versions prior to 19.2R1-S4, 19.2R2. This issue does not affect Juniper Networks Junos OS prior to version 16.1R1.

Published: April 08, 2020; 4:15:14 PM -0400
V4.0:(not available)
V3.1: 5.9 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2020-1617

This issue occurs on Juniper Networks Junos OS devices which do not support Advanced Forwarding Interface (AFI) / Advanced Forwarding Toolkit (AFT). Devices using AFI and AFT are not exploitable to this issue. An improper initialization of memory in the packet forwarding architecture in Juniper Networks Junos OS non-AFI/AFT platforms which may lead to a Denial of Service (DoS) vulnerability being exploited when a genuine packet is received and inspected by non-AFT/AFI sFlow and when the device is also configured with firewall policers. This first genuine packet received and inspected by sampled flow (sFlow) through a specific firewall policer will cause the device to reboot. After the reboot has completed, if the device receives and sFlow inspects another genuine packet seen through a specific firewall policer, the device will generate a core file and reboot. Continued inspection of these genuine packets will create an extended Denial of Service (DoS) condition. Depending on the method for service restoration, e.g. hard boot or soft reboot, a core file may or may not be generated the next time the packet is received and inspected by sFlow. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S9, 17.4R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.1 versions prior to 18.1R3-S9 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D30 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2 versions prior to 18.2R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.3 versions prior to 18.3R3 on PTX1000 and PTX10000 Series, QFX10000 Series. This issue is not applicable to Junos OS versions before 17.4R1. This issue is not applicable to Junos OS Evolved or Junos OS with Advanced Forwarding Toolkit (AFT) forwarding implementations which use a different implementation of sFlow. The following example information is unrelated to this issue and is provided solely to assist you with determining if you have AFT or not. Example: A Junos OS device which supports the use of EVPN signaled VPWS with Flexible Cross Connect uses the AFT implementation. Since this configuration requires support and use of the AFT implementation to support this configuration, the device is not vulnerable to this issue as the sFlow implementation is different using the AFT architecture. For further details about AFT visit the AFI / AFT are in the links below. If you are uncertain if you use the AFI/AFT implementation or not, there are configuration examples in the links below which you may use to determine if you are vulnerable to this issue or not. If the commands work, you are. If not, you are not. You may also use the Feature Explorer to determine if AFI/AFT is supported or not. If you are still uncertain, please contact your support resources.

Published: April 08, 2020; 4:15:13 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH