CVE-2016-10370

An issue was discovered on OnePlus devices such as the 3T. The OnePlus OTA Updater pushes the signed-OTA image over HTTP without TLS. While it does not allow for installation of arbitrary OTAs (due to the digital signature), it unnecessarily increases the attack surface, and allows for remote exploitation of other vulnerabilities such as CVE-2017-5948, CVE-2017-8850, and CVE-2017-8851.

Published: May 11, 2017; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2017-8899

Invision Power Services (IPS) Community Suite 4.1.19.2 and earlier has a composite of Stored XSS and Information Disclosure issues in the attachments feature found in User CP. This can be triggered by any Invision Power Board user and can be used to gain access to moderator/admin accounts. The primary cause is the ability to upload an SVG document with a crafted attribute such an onload; however, full path disclosure is required for exploitation.

Published: May 11, 2017; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 8.1 HIGH
V2.0: 6.8 MEDIUM
CVE-2017-8898

Invision Power Services (IPS) Community Suite 4.1.19.2 and earlier has stored XSS in the Announcements, allowing privilege escalation from an Invision Power Board moderator to an admin. An attack uses the announce_content parameter in an index.php?/modcp/announcements/&action=create request. This is related to the "<> Source" option.

Published: May 11, 2017; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-8897

Invision Power Services (IPS) Community Suite 4.1.19.2 and earlier has pre-auth reflected XSS in the IPS UTF8 Converter v1.1.18: admin/convertutf8/index.php?controller= is the attack vector. This UTF8 Converter vulnerability can easily be used to make a malicious announcement affecting any Invision Power Board user who views the announcement.

Published: May 11, 2017; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2016-7476

The Traffic Management Microkernel (TMM) in F5 BIG-IP LTM, AAM, AFM, APM, ASM, GTM, Link Controller, PEM, PSM, and WebSafe 11.6.0 before 11.6.0 HF6, 11.5.0 before 11.5.3 HF2, and 11.3.0 before 11.4.1 HF10 may suffer from a memory leak while handling certain types of TCP traffic. Remote attackers may cause a denial of service (DoS) by way of a crafted TCP packet.

Published: May 11, 2017; 12:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-9100

Symantec Advanced Secure Gateway (ASG) 6.6 prior to 6.6.5.13, ASG 6.7 prior to 6.7.3.1, ProxySG 6.5 prior to 6.5.10.6, ProxySG 6.6 prior to 6.6.5.13, and ProxySG 6.7 prior to 6.7.3.1 are susceptible to an information disclosure vulnerability. An attacker with local access to the client host of an authenticated administrator user can, under certain circumstances, obtain sensitive authentication credential information.

Published: May 11, 2017; 10:30:16 AM -0400
V4.0:(not available)
V3.0: 7.8 HIGH
V2.0: 2.1 LOW
CVE-2016-9099

Symantec Advanced Secure Gateway (ASG) 6.6, ASG 6.7 prior to 6.7.2.1, ProxySG 6.5 prior to 6.5.10.6, ProxySG 6.6, and ProxySG 6.7 prior to 6.7.2.1 are susceptible to an open redirection vulnerability. A remote attacker can use a crafted management console URL in a phishing attack to redirect the target user to a malicious web site.

Published: May 11, 2017; 10:30:16 AM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 5.8 MEDIUM
CVE-2016-9097

The Symantec Advanced Secure Gateway (ASG) 6.6 prior to 6.6.5.8, ProxySG 6.5 prior 6.5.10.6, ProxySG 6.6 prior to 6.6.5.8, and ProxySG 6.7 prior to 6.7.1.2 management consoles do not, under certain circumstances, correctly authorize administrator users. A malicious administrator with read-only access can exploit this vulnerability to access management console functionality that requires read-write access privileges.

Published: May 11, 2017; 10:30:16 AM -0400
V4.0:(not available)
V3.0: 7.2 HIGH
V2.0: 8.0 HIGH
CVE-2016-9092

The Symantec Content Analysis (CA) 1.3, 2.x prior to 2.2.1.1, and Mail Threat Defense (MTD) 1.1 management consoles are susceptible to a cross-site request forging (CSRF) vulnerability. A remote attacker can use phishing or other social engineering techniques to access the management console with the privileges of an authenticated administrator user.

Published: May 11, 2017; 10:30:16 AM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2016-2126

Samba version 4.0.0 up to 4.5.2 is vulnerable to privilege elevation due to incorrect handling of the PAC (Privilege Attribute Certificate) checksum. A remote, authenticated, attacker can cause the winbindd process to crash using a legitimate Kerberos ticket. A local service with access to the winbindd privileged pipe can cause winbindd to cache elevated access permissions.

Published: May 11, 2017; 10:29:58 AM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2015-5436

A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020.

Published: May 11, 2017; 10:29:46 AM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2017-6867

A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.

Published: May 11, 2017; 6:29:00 AM -0400
V4.0:(not available)
V3.0: 4.9 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2017-6865

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.

Published: May 11, 2017; 6:29:00 AM -0400
V4.0:(not available)
V3.0: 6.5 MEDIUM
V2.0: 6.1 MEDIUM
CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices.

Published: May 11, 2017; 6:29:00 AM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 6.1 MEDIUM
CVE-2017-8798

Integer signedness error in MiniUPnP MiniUPnPc v1.4.20101221 through v2.0 allows remote attackers to cause a denial of service or possibly have unspecified other impact.

Published: May 10, 2017; 9:29:06 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-5461

Mozilla Network Security Services (NSS) before 3.21.4, 3.22.x through 3.28.x before 3.28.4, 3.29.x before 3.29.5, and 3.30.x before 3.30.1 allows remote attackers to cause a denial of service (out-of-bounds write) or possibly have unspecified other impact by leveraging incorrect base64 operations.

Published: May 10, 2017; 9:29:05 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

Published: May 10, 2017; 9:29:05 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 6.1 MEDIUM
CVE-2017-8895

In Veritas Backup Exec 2014 before build 14.1.1187.1126, 15 before build 14.2.1180.3160, and 16 before FP1, there is a use-after-free vulnerability in multiple agents that can lead to a denial of service or remote code execution. An unauthenticated attacker can use this vulnerability to crash the agent or potentially take control of the agent process and then the system it is running on.

Published: May 10, 2017; 5:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2017-8892

Cross-site scripting (XSS) vulnerability in OpenText Tempo Box 10.0.3 allows remote attackers to inject arbitrary web script or HTML persistently via the name of an uploaded image.

Published: May 10, 2017; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2017-8852

SAP SAPCAR 721.510 has a Heap Based Buffer Overflow Vulnerability. It could be exploited with a crafted CAR archive file received from an untrusted remote source. The problem is that the length of data written is an arbitrary number found within the file. The vendor response is SAP Security Note 2441560.

Published: May 10, 2017; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 7.8 HIGH
V2.0: 6.8 MEDIUM