U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
  • Keyword (text search): cpe:2.3:a:siemens:sinema_remote_connect_server:1.0:sp3_hf1:*:*:*:*:*:*
  • CPE Name Search: true
There are 52 matching records.
Displaying matches 41 through 52.
Vuln ID Summary CVSS Severity
CVE-2021-22924

libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate.

Published: August 05, 2021; 5:15:11 PM -0400
V3.1: 3.7 LOW
V2.0: 4.3 MEDIUM
CVE-2021-20093

A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server.

Published: June 16, 2021; 8:15:12 AM -0400
V3.1: 9.1 CRITICAL
V2.0: 6.4 MEDIUM
CVE-2020-25240

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.

Published: March 15, 2021; 1:15:20 PM -0400
V3.1: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2020-25239

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.

Published: March 15, 2021; 1:15:19 PM -0400
V3.1: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2020-7595

xmlStringLenDecodeEntities in parser.c in libxml2 2.9.10 has an infinite loop in a certain end-of-file situation.

Published: January 21, 2020; 6:15:13 PM -0500
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-19956

xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc->oldNs.

Published: December 24, 2019; 11:15:11 AM -0500
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-13922

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: September 13, 2019; 1:15:11 PM -0400
V3.1: 2.7 LOW
V2.0: 4.0 MEDIUM
CVE-2019-13920

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: September 13, 2019; 1:15:11 PM -0400
V3.1: 4.3 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2019-13919

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: September 13, 2019; 1:15:11 PM -0400
V3.1: 4.3 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2019-13918

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: September 13, 2019; 1:15:11 PM -0400
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2019-6570

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.

Published: April 17, 2019; 10:29:03 AM -0400
V3.1: 8.8 HIGH
V2.0: 9.0 HIGH
CVE-2016-6204

Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

Published: July 22, 2016; 11:59:04 AM -0400
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM