Search Results (Refine Search)
- Keyword (text search): OPC
- Search Type: Search All
Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2020-8479 |
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. Published: April 28, 2020; 10:15:11 PM -0400 |
V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2020-8478 |
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder. Published: April 28, 2020; 10:15:11 PM -0400 |
V3.1: 3.3 LOW V2.0: 2.1 LOW |
CVE-2020-8476 |
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service. Published: April 28, 2020; 10:15:11 PM -0400 |
V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2020-8475 |
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service. Published: April 28, 2020; 10:15:11 PM -0400 |
V3.1: 7.5 HIGH V2.0: 2.1 LOW |
CVE-2020-8471 |
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code. Published: April 28, 2020; 10:15:11 PM -0400 |
V3.1: 7.8 HIGH V2.0: 4.6 MEDIUM |
CVE-2020-8472 |
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. Published: April 28, 2020; 8:15:12 PM -0400 |
V3.1: 7.8 HIGH V2.0: 6.8 MEDIUM |
CVE-2020-8867 |
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of OPC Foundation UA .NET Standard 1.04.358.30. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of sessions. The issue results from the lack of proper locking when performing operations on an object. An attacker can leverage this vulnerability to create a denial-of-service condition against the application. Was ZDI-CAN-10295. Published: April 22, 2020; 5:15:14 PM -0400 |
V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-5105 |
An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System). Published: March 26, 2020; 11:15:24 AM -0400 |
V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-19135 |
In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network. Published: March 16, 2020; 12:15:11 PM -0400 |
V3.1: 7.4 HIGH V2.0: 5.8 MEDIUM |
CVE-2019-10567 |
There is a way to deceive the GPU kernel driver into thinking there is room in the GPU ringbuffer and overwriting existing commands could allow unintended GPU opcodes to be executed in Snapdragon Auto, Snapdragon Compute, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables in APQ8009, APQ8017, APQ8053, APQ8096AU, APQ8098, MDM9150, MDM9206, MDM9207C, MDM9607, MDM9650, MSM8909W, MSM8917, MSM8920, MSM8937, MSM8940, MSM8953, MSM8996AU, MSM8998, Nicobar, QCS405, QCS605, QM215, Rennell, SA6155P, Saipan, SC8180X, SDA660, SDA845, SDM429, SDM429W, SDM439, SDM450, SDM630, SDM632, SDM636, SDM660, SDM670, SDM710, SDM845, SDX20, SDX24, SDX55, SM6150, SM7150, SM8150, SM8250, SXR1130, SXR2130 Published: February 07, 2020; 12:15:11 AM -0500 |
V3.1: 7.8 HIGH V2.0: 7.2 HIGH |
CVE-2015-5628 |
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to execute arbitrary code via a crafted packet. Published: February 05, 2020; 2:15:10 PM -0500 |
V3.1: 9.8 CRITICAL V2.0: 10.0 HIGH |
CVE-2015-5627 |
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (process outage) via a crafted packet. Published: February 05, 2020; 2:15:10 PM -0500 |
V3.1: 9.8 CRITICAL V2.0: 10.0 HIGH |
CVE-2015-5626 |
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (network-communications outage) via a crafted packet. Published: February 05, 2020; 2:15:10 PM -0500 |
V3.1: 9.8 CRITICAL V2.0: 10.0 HIGH |
CVE-2019-19802 |
In Gallagher Command Centre Server v8.10 prior to v8.10.1134(MR4), v8.00 prior to v8.00.1161(MR5), v7.90 prior to v7.90.991(MR5), v7.80 prior to v7.80.960(MR2) and v7.70 or earlier, an authenticated user connecting to OPCUA can view all data that would be replicated in a multi-server setup without privilege checks being applied. Published: January 16, 2020; 9:15:11 PM -0500 |
V3.1: 6.5 MEDIUM V2.0: 4.0 MEDIUM |
CVE-2020-7045 |
In Wireshark 3.0.x before 3.0.8, the BT ATT dissector could crash. This was addressed in epan/dissectors/packet-btatt.c by validating opcodes. Published: January 15, 2020; 11:15:11 PM -0500 |
V3.1: 6.5 MEDIUM V2.0: 3.3 LOW |
CVE-2019-12068 |
In QEMU 1:4.1-1, 1:2.1+dfsg-12+deb8u6, 1:2.8+dfsg-6+deb9u8, 1:3.1+dfsg-8~deb10u1, 1:3.1+dfsg-8+deb10u2, and 1:2.1+dfsg-12+deb8u12 (fixed), when executing script in lsi_execute_script(), the LSI scsi adapter emulator advances 's->dsp' index to read next opcode. This can lead to an infinite loop if the next opcode is empty. Move the existing loop exit after 10k iterations so that it covers no-op opcodes as well. Published: September 24, 2019; 4:15:11 PM -0400 |
V3.1: 3.8 LOW V2.0: 2.1 LOW |
CVE-2019-16705 |
Ming (aka libming) 0.4.8 has an out of bounds read vulnerability in the function OpCode() in the decompile.c file in libutil.a. Published: September 23, 2019; 1:15:10 AM -0400 |
V3.1: 9.1 CRITICAL V2.0: 6.4 MEDIUM |
CVE-2019-13542 |
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. Published: September 17, 2019; 3:15:10 PM -0400 |
V3.1: 6.5 MEDIUM V2.0: 4.0 MEDIUM |
CVE-2019-5017 |
An exploitable information disclosure vulnerability exists in the KCodes NetUSB.ko kernel module that enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. An unauthenticated, remote attacker can craft and send a packet containing an opcode that will trigger the kernel module to return several addresses. One of which can be used to calculate the dynamic base address of the module for further exploitation. Published: June 17, 2019; 5:15:09 PM -0400 |
V3.1: 5.3 MEDIUM V2.0: 5.0 MEDIUM |
CVE-2019-11412 |
An issue was discovered in Artifex MuJS 1.0.5. jscompile.c can cause a denial of service (invalid stack-frame jump) because it lacks an ENDTRY opcode call. Published: April 22, 2019; 7:29:05 AM -0400 |
V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |