U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
There are 243,830 matching records.
Displaying matches 127,061 through 127,080.
Vuln ID Summary CVSS Severity
CVE-2018-7845

A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-7843

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-7842

A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2018-7841

A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2018-7840

A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 7.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2018-7834

A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2018-7829

An Improper Neutralization of Special Elements in Query vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which allows an attacker to execute arbitrary system commands.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 9.0 HIGH
CVE-2018-7828

A Cross-Site Request Forgery (CSRF) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera when an authenticated user clicks a specially crafted malicious link while logged into the camera.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2018-7827

A Cross-Site Scripting (XSS) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which a remote attacker can execute arbitrary HTML and script code in a user’s browser session.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2018-7826

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2018-7825

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2018-7824

An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 4.9 MEDIUM
V2.0: 6.8 MEDIUM
CVE-2018-7823

A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2018-7822

An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0: 2.1 LOW
CVE-2018-7821

An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated.

Published: May 22, 2019; 4:29:01 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-7816

A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file.

Published: May 22, 2019; 4:29:00 PM -0400
V4.0:(not available)
V3.0: 6.5 MEDIUM
V2.0: 5.5 MEDIUM
CVE-2018-7788

A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection.

Published: May 22, 2019; 4:29:00 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2017-9808

OX Software GmbH OX App Suite 7.8.4 and earlier is affected by: Cross Site Scripting (XSS).

Published: May 22, 2019; 4:29:00 PM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2017-8777

Open-Xchange GmbH OX Cloud Plugins 1.4.0 and earlier is affected by: Missing Authorization.

Published: May 22, 2019; 4:29:00 PM -0400
V4.0:(not available)
V3.0: 7.2 HIGH
V2.0: 6.5 MEDIUM
CVE-2017-8341

Open-Xchange GmbH OX App Suite 7.8.3 and earlier is affected by: Content Spoofing.

Published: May 22, 2019; 4:29:00 PM -0400
V4.0:(not available)
V3.0: 5.3 MEDIUM
V2.0: 5.0 MEDIUM