Search Results (Refine Search)
- Results Type: Overview
Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2019-11873 |
wolfSSL 4.0.0 has a Buffer Overflow in DoPreSharedKeys in tls13.c when a current identity size is greater than a client identity size. An attacker sends a crafted hello client packet over the network to a TLSv1.3 wolfSSL server. The length fields of the packet: record length, client hello length, total extensions length, PSK extension length, total identity length, and identity length contain their maximum value which is 2^16. The identity data field of the PSK extension of the packet contains the attack data, to be stored in the undefined memory (RAM) of the server. The size of the data is about 65 kB. Possibly the attacker can perform a remote code execution attack. Published: May 23, 2019; 9:29:07 AM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2019-12295 |
In Wireshark 3.0.0 to 3.0.1, 2.6.0 to 2.6.8, and 2.4.0 to 2.4.14, the dissection engine could crash. This was addressed in epan/packet.c by restricting the number of layers and consequently limiting recursion. Published: May 23, 2019; 8:29:00 AM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-12293 |
In Poppler through 0.76.1, there is a heap-based buffer over-read in JPXStream::init in JPEG2000Stream.cc via data with inconsistent heights or widths. Published: May 23, 2019; 1:29:00 AM -0400 |
V4.0:(not available) V3.0: 8.8 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-6808 |
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2019-6807 |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-6806 |
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7857 |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7856 |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7855 |
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7854 |
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7853 |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7844 |
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2018-7803 |
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.0: 5.9 MEDIUM V2.0: 4.3 MEDIUM |
CVE-2018-7201 |
CSV Injection was discovered in ProjectSend before r1053, affecting victims who import the data into Microsoft Excel. Published: May 22, 2019; 5:29:00 PM -0400 |
V4.0:(not available) V3.0: 8.8 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-6821 |
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. Published: May 22, 2019; 4:29:02 PM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 6.4 MEDIUM |
CVE-2019-6820 |
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 Published: May 22, 2019; 4:29:02 PM -0400 |
V4.0:(not available) V3.1: 8.2 HIGH V2.0: 6.4 MEDIUM |
CVE-2019-6819 |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium. Published: May 22, 2019; 4:29:02 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-6816 |
In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. Published: May 22, 2019; 4:29:02 PM -0400 |
V4.0:(not available) V3.0: 9.1 CRITICAL V2.0: 6.4 MEDIUM |
CVE-2019-6815 |
In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. Published: May 22, 2019; 4:29:02 PM -0400 |
V4.0:(not available) V3.0: 9.1 CRITICAL V2.0: 6.4 MEDIUM |
CVE-2019-6814 |
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI. Published: May 22, 2019; 4:29:01 PM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |