CVE-2023-39474

Inductive Automation Ignition downloadLaunchClientJar Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server. The specific flaw exists within the downloadLaunchClientJar function. The issue results from the lack of validating a remote JAR file prior to loading it. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-19915.

Published: May 02, 2024; 11:15:13 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39473

Inductive Automation Ignition AbstractGatewayFunction Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the AbstractGatewayFunction class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17587.

Published: May 02, 2024; 11:15:13 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39472

Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM. . Was ZDI-CAN-17571.

Published: May 02, 2024; 11:15:13 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39471

TP-Link TL-WR841N ated_tp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link TL-WR841N routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ated_tp service. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21825.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39469

PaperCut NG External User Lookup Code Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of PaperCut NG. Authentication is required to exploit this vulnerability. The specific flaw exists within the External User Lookup functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute Java code. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21013.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39468

Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39467

Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39466

Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39465

Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.

Published: May 02, 2024; 11:15:12 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39464

Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.

Published: May 02, 2024; 11:15:11 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39463

Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537.

Published: May 02, 2024; 11:15:11 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39462

Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536.

Published: May 02, 2024; 11:15:11 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39461

Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.

Published: May 02, 2024; 11:15:11 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39460

Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.

Published: May 02, 2024; 11:15:11 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39459

Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531.

Published: May 02, 2024; 11:15:10 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39458

Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509.

Published: May 02, 2024; 11:15:10 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-39457

Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.

Published: May 02, 2024; 11:15:10 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-38125

Softing edgeAggregator Permissive Cross-domain Policy with Untrusted Domains Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing edgeAggregator. Authentication is required to exploit this vulnerability. The specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20542.

Published: May 02, 2024; 11:15:10 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-38124

Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the Ignition Gateway server. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20541.

Published: May 02, 2024; 11:15:10 PM -0400
V4.0:(not available)
V3.x:(not available)
V2.0:(not available)
CVE-2023-41222

D-Link DIR-3040 prog.cgi SetWan2Settings Stack-Based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-3040 routers. Authentication is required to exploit this vulnerability. The specific flaw exists within the prog.cgi binary, which handles HNAP requests made to the lighttpd webserver listening on TCP ports 80 and 443. The issue results from the lack of proper validation of a user-supplied string before copying it to a fixed-size stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21622.

Published: May 02, 2024; 10:15:56 PM -0400