CVE-2017-6046

An Insufficiently Protected Credentials issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Sensitive information is insufficiently protected during transmission and vulnerable to sniffing, which could lead to information disclosure.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2017-6044

An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2017-6042

A Cross-Site Request Forgery issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Affected devices do not verify if a request was intentionally sent by the logged-in user, which may allow an attacker to trick a client into making an unintentional request to the web server that will be treated as an authentic request.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2017-6041

An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-6040

An Information Exposure issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. Non-sensitive information can be obtained anonymously.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2017-6038

A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 7.1 HIGH
V2.0: 5.8 MEDIUM
CVE-2017-6036

A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 6.5 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2017-6034

An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-6032

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2017-6030

A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.

Published: June 29, 2017; 11:29:00 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 6.4 MEDIUM
CVE-2017-6028

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Published: June 29, 2017; 11:29:00 PM -0400
V3.1: 9.8 CRITICAL
V2.0: 5.0 MEDIUM
CVE-2017-6026

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.

Published: June 29, 2017; 11:29:00 PM -0400
V3.1: 9.1 CRITICAL
V2.0: 6.4 MEDIUM
CVE-2017-6022

A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-6018

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 6.1 MEDIUM
V2.0: 5.8 MEDIUM
CVE-2017-6017

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2016-9358

A Hard-Coded Passwords issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. The end user does not have the ability to change system passwords.

Published: June 29, 2017; 11:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2017-10688

In LibTIFF 4.0.8, there is a assertion abort in the TIFFWriteDirectoryTagCheckedLong8Array function in tif_dirwrite.c. A crafted input will lead to a remote denial of service attack.

Published: June 29, 2017; 7:29:00 PM -0400
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2017-10687

In LibSass 3.4.5, there is a heap-based buffer over-read in the function json_mkstream() in sass_context.cpp. A crafted input will lead to a remote denial of service attack.

Published: June 29, 2017; 7:29:00 PM -0400
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2017-10686

In Netwide Assembler (NASM) 2.14rc0, there are multiple heap use after free vulnerabilities in the tool nasm. The related heap is allocated in the token() function and freed in the detoken() function (called by pp_getline()) - it is used again at multiple positions later that could cause multiple damages. For example, it causes a corrupted double-linked list in detoken(), a double free or corruption in delete_Token(), and an out-of-bounds write in detoken(). It has a high possibility to lead to a remote code execution attack.

Published: June 29, 2017; 7:29:00 PM -0400
V3.0: 7.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2017-10685

In ncurses 6.0, there is a format string vulnerability in the fmt_entry function. A crafted input will lead to a remote arbitrary code execution attack.

Published: June 29, 2017; 7:29:00 PM -0400
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH