Search Results (Refine Search)

Search Parameters:
There are 267,044 matching records.
Displaying matches 86,081 through 86,100.
Vuln ID Summary CVSS Severity
CVE-2022-31207

The Omron SYSMAC Cx product family PLCs (CS series, CJ series, and CP series) through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS (9600/TCP) protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication flaws as reported in FSCT-2022-0057. Control logic is downloaded to PLC volatile memory using the FINS Program Area Read and Program Area Write commands or to non-volatile memory using other commands from where it can be loaded into volatile memory for execution. The logic that is loaded into and executed from the user program area exists in compiled object code form. Upon execution, these object codes are first passed to a dedicated ASIC that determines whether the object code is to be executed by the ASIC or the microprocessor. In the former case, the object code is interpreted by the ASIC whereas in the latter case the object code is passed to the microprocessor for object code interpretation by a ROM interpreter. In the abnormal case where the object code cannot be handled by either, an abnormal condition is triggered and the PLC is halted. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, thus allowing an attacker to manipulate transmitted object code to the PLC and either execute arbitrary object code commands on the ASIC or on the microprocessor interpreter.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-31206

The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-31205

In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2022-31204

Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2022-30275

The Motorola MOSCAD Toolbox software through 2022-05-02 relies on a cleartext password. It utilizes an MDLC driver to communicate with MOSCAD/ACE RTUs for engineering purposes. Access to these communications is protected by a password stored in cleartext in the wmdlcdrv.ini driver configuration file. In addition, this password is used for access control to MOSCAD/STS projects protected with the Legacy Password feature. In this case, an insecure CRC of the password is present in the project file: this CRC is validated against the password in the driver configuration file.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2022-30273

The Motorola MDLC protocol through 2022-05-02 mishandles message integrity. It supports three security modes: Plain, Legacy Encryption, and New Encryption. In Legacy Encryption mode, traffic is encrypted via the Tiny Encryption Algorithm (TEA) block-cipher in ECB mode. This mode of operation does not offer message integrity and offers reduced confidentiality above the block level, as demonstrated by an ECB Penguin attack against any block ciphers.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-29965

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. Access to privileged operations on the maintenance port TELNET interface (23/TCP) on M-series and SIS (CSLS/LSNB/LSNG) nodes is controlled by means of utility passwords. These passwords are generated using a deterministic, insecure algorithm using a single seed value composed of a day/hour/minute timestamp with less than 16 bits of entropy. The seed value is fed through a lookup table and a series of permutation operations resulting in three different four-character passwords corresponding to different privilege levels. An attacker can easily reconstruct these passwords and thus gain access to privileged maintenance operations. NOTE: this is different from CVE-2014-2350.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0:(not available)
CVE-2022-29964

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0:(not available)
CVE-2022-29963

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0:(not available)
CVE-2022-29962

The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0:(not available)
CVE-2022-29960

Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities.

Published: July 26, 2022; 6:15:11 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0:(not available)
CVE-2022-29958

JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory address and a blob of machine code. The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to execute arbitrary machine code on the PLC's CPU module in the context of the runtime. In the case of the PC10G-CPU, and likely for other CPU modules of the TOYOPUC family, a processor without MPU or MMU is used and this no memory protection or privilege-separation capabilities are available, giving an attacker full control over the CPU.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-29957

The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0:(not available)
CVE-2022-29953

The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2022-29952

Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 9.1 CRITICAL
V2.0:(not available)
CVE-2022-29951

JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 9.1 CRITICAL
V2.0:(not available)
CVE-2022-27105

InMailX Outlook Plugin < 3.22.0101 is vulnerable to Cross Site Scripting (XSS). InMailX Connection names are not sanitzed in the Outlook tab, which allows a local user or network administrator to execute HTML / Javascript in the Outlook of users.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 5.4 MEDIUM
V2.0:(not available)
CVE-2022-1641

Use after free in Web UI Diagnostics in Google Chrome on Chrome OS prior to 101.0.4951.64 allowed a remote attacker who convinced a user to engage in specific UI interactions to potentially exploit heap corruption via specific user interaction.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0:(not available)
CVE-2022-1640

Use after free in Sharing in Google Chrome prior to 101.0.4951.64 allowed a remote attacker who convinced a user to engage in specific UI interactions to potentially exploit heap corruption via a crafted HTML page.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0:(not available)
CVE-2022-1639

Use after free in ANGLE in Google Chrome prior to 101.0.4951.64 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.

Published: July 26, 2022; 6:15:10 PM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0:(not available)