U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
There are 267,078 matching records.
Displaying matches 92,041 through 92,060.
Vuln ID Summary CVSS Severity
CVE-2022-23722

When a password reset mechanism is configured to use the Authentication API with an Authentication Policy, email One-Time Password, PingID or SMS authentication, an existing user can reset another existing user’s password.

Published: May 02, 2022; 6:15:09 PM -0400
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 3.5 LOW
CVE-2022-29444

Plugin Settings Change leading to Cross-Site Scripting (XSS) vulnerability in Cloudways Breeze plugin <= 2.0.2 on WordPress allows users with a subscriber or higher user role to execute any of the wp_ajax_* actions in the class Breeze_Configuration which includes the ability to change any of the plugin's settings including CDN setting which could be further used for XSS attack.

Published: May 02, 2022; 4:15:08 PM -0400
V4.0:(not available)
V3.1: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2021-41810

Admin tool allows storing configuration data with script which may then get run by another vault administrator. Requires vault admin level authentication and is not remotely exploitable

Published: May 02, 2022; 4:15:08 PM -0400
V4.0:(not available)
V3.1: 4.8 MEDIUM
V2.0: 3.5 LOW
CVE-2021-36844

Authenticated (admin+) Stored Cross-Site Scripting (XSS) vulnerability in MyThemeShop WP Subscribe plugin <= 1.2.12 on WordPress.

Published: May 02, 2022; 4:15:07 PM -0400
V4.0:(not available)
V3.1: 4.8 MEDIUM
V2.0: 3.5 LOW
CVE-2022-28613

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.

Published: May 02, 2022; 3:15:09 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2022-26326

Potential open redirection vulnerability when URL is crafted in specific format in NetIQ Access Manager prior to 5.0.2

Published: May 02, 2022; 3:15:09 PM -0400
V4.0:(not available)
V3.1: 6.1 MEDIUM
V2.0: 5.8 MEDIUM
CVE-2022-26325

Reflected Cross Site Scripting (XSS) vulnerability in NetIQ Access Manager prior to 5.0.2

Published: May 02, 2022; 3:15:09 PM -0400
V4.0:(not available)
V3.1: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2022-1515

A memory leak was discovered in matio 1.5.21 and earlier in Mat_VarReadNextInfo5() in mat5.c via a crafted file. This issue can potentially result in DoS.

Published: May 02, 2022; 3:15:09 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2022-1475

An integer overflow vulnerability was found in FFmpeg versions before 4.4.2 and before 5.0.1 in g729_parse() in llibavcodec/g729_parser.c when processing a specially crafted file.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 5.5 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2022-1378

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1377

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1376

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1375

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1374

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1372

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1371

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegf. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1370

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadREGbyID. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1369

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2022-1367

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2021-3750

A DMA reentrancy issue was found in the USB EHCI controller emulation of QEMU. EHCI does not verify if the Buffer Pointer overlaps with its MMIO region when it transfers the USB packets. Crafted content may be written to the controller's registers and trigger undesirable actions (such as reset) while the device is still transferring packets. This can ultimately lead to a use-after-free issue. A malicious guest could use this flaw to crash the QEMU process on the host, resulting in a denial of service condition, or potentially execute arbitrary code within the context of the QEMU process on the host. This flaw affects QEMU versions before 7.0.0.

Published: May 02, 2022; 3:15:08 PM -0400
V4.0:(not available)
V3.1: 8.2 HIGH
V2.0: 4.6 MEDIUM