CVE-2017-4979

EMC Isilon OneFS 8.0.1.0, OneFS 8.0.0.0 - 8.0.0.2, OneFS 7.2.1.0 - 7.2.1.3, and OneFS 7.2.0.x is affected by an NFS export vulnerability. Under certain conditions, after upgrading a cluster from OneFS 7.1.1.x or earlier, users may have unexpected levels of access to some NFS exports.

Published: May 19, 2017; 11:29:00 AM -0400
V4.0:(not available)
V3.0: 7.1 HIGH
V2.0: 4.6 MEDIUM
CVE-2017-4978

EMC RSA Adaptive Authentication (On-Premise) versions prior to 7.3 P2 (exclusive) contains a fix for a cross-site scripting vulnerability that could potentially be exploited by malicious users to compromise the affected system.

Published: May 19, 2017; 11:29:00 AM -0400
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2017-9079

Dropbear before 2017.75 might allow local users to read certain files as root, if the file has the authorized_keys file format with a command= option. This occurs because ~/.ssh/authorized_keys is read with root privileges and symlinks are followed.

Published: May 19, 2017; 10:29:00 AM -0400
V4.0:(not available)
V3.0: 4.7 MEDIUM
V2.0: 4.7 MEDIUM
CVE-2017-9078

The server in Dropbear before 2017.75 might allow post-authentication root remote code execution because of a double free in cleanup of TCP listeners when the -a option is enabled.

Published: May 19, 2017; 10:29:00 AM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 8.5 HIGH
CVE-2017-9077

The tcp_v6_syn_recv_sock function in net/ipv6/tcp_ipv6.c in the Linux kernel through 4.11.1 mishandles inheritance, which allows local users to cause a denial of service or possibly have unspecified other impact via crafted system calls, a related issue to CVE-2017-8890.

Published: May 19, 2017; 10:29:00 AM -0400
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 7.2 HIGH
CVE-2017-9076

The dccp_v6_request_recv_sock function in net/dccp/ipv6.c in the Linux kernel through 4.11.1 mishandles inheritance, which allows local users to cause a denial of service or possibly have unspecified other impact via crafted system calls, a related issue to CVE-2017-8890.

Published: May 19, 2017; 3:29:00 AM -0400
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 7.2 HIGH
CVE-2017-9075

The sctp_v6_create_accept_sk function in net/sctp/ipv6.c in the Linux kernel through 4.11.1 mishandles inheritance, which allows local users to cause a denial of service or possibly have unspecified other impact via crafted system calls, a related issue to CVE-2017-8890.

Published: May 19, 2017; 3:29:00 AM -0400
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 7.2 HIGH
CVE-2017-9074

The IPv6 fragmentation implementation in the Linux kernel through 4.11.1 does not consider that the nexthdr field may be associated with an invalid option, which allows local users to cause a denial of service (out-of-bounds read and BUG) or possibly have unspecified other impact via crafted socket and send system calls.

Published: May 19, 2017; 3:29:00 AM -0400
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 7.2 HIGH
CVE-2017-7937

An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 4.0 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2017-7935

A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device's availability by performing multiple initial VPN requests.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2017-7907

An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 6.6 MEDIUM
V2.0: 3.3 LOW
CVE-2017-6048

A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet Solar Datalogger V5.03-1.56a and prior, and SenNet Multitask Meter V5.21a-1.18b and prior. Successful exploitation of this vulnerability could result in the attacker breaking out of the jailed shell and gaining full access to the system.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 9.0 HIGH
CVE-2017-6027

An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-6025

A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-6016

An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 7.3 HIGH
V2.0: 4.4 MEDIUM
CVE-2017-5177

A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2017-5176

A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 7.0 HIGH
V2.0: 6.2 MEDIUM
CVE-2017-5174

An Authentication Bypass issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An authentication bypass vulnerability has been identified. The existing file system architecture could allow attackers to bypass the access control that may allow remote code execution.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2017-5173

An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An improper neutralization of special elements vulnerability has been identified. If special elements are not properly neutralized, an attacker can call multiple parameters that can allow access to the root level operating system which could allow remote code execution.

Published: May 18, 2017; 11:29:00 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2017-6652

A vulnerability in the web framework of the Cisco TelePresence IX5000 Series could allow an unauthenticated, remote attacker to access arbitrary files on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by using directory traversal techniques to read files within the Cisco TelePresence IX5000 Series filesystem. This vulnerability affects Cisco TelePresence IX5000 Series devices running software version 8.2.0. Cisco Bug IDs: CSCvc52325.

Published: May 18, 2017; 3:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH