U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
  • Keyword (text search): cpe:2.3:o:juniper:junos:18.3:r1:*:*:*:*:*:*
There are 180 matching records.
Displaying matches 141 through 160.
Vuln ID Summary CVSS Severity
CVE-2020-1625

The kernel memory usage represented as "temp" via 'show system virtual-memory' may constantly increase when Integrated Routing and Bridging (IRB) is configured with multiple underlay physical interfaces, and one interface flaps. This memory leak can affect running daemons (processes), leading to an extended Denial of Service (DoS) condition. Usage of "temp" virtual memory, shown here by a constantly increasing value of outstanding Requests, can be monitored by executing the 'show system virtual-memory' command as shown below: user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 10551 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6460 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 16101 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6665 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 21867 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6858 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S5, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2. This issue does not affect Juniper Networks Junos OS 12.3 and 15.1.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 3.3 LOW
CVE-2020-1619

A privilege escalation vulnerability in Juniper Networks QFX10K Series, EX9200 Series, MX Series, and PTX Series with Next-Generation Routing Engine (NG-RE), allows a local authenticated high privileged user to access the underlying WRL host. This issue only affects QFX10K Series with NG-RE, EX9200 Series with NG-RE, MX Series with NG-RE and PTX Series with NG-RE; which uses vmhost. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S4; 18.2 versions prior to 18.2R3; 18.2X75 versions prior to 18.2X75-D50; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2. To identify whether the device has NG-RE with vmhost, customer can run the following command: > show vmhost status Compute cluster: rainier-re-cc Compute Node: rainier-re-cn, Online If the "show vmhost status" is not supported, then the device does not have NG-RE with vmhost.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 6.7 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2020-1618

On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as root without any password. This issue might only occur in certain scenarios: • At the first reboot after performing device factory reset using the command “request system zeroize”; or • A temporary moment during the first reboot after the software upgrade when the device configured in Virtual Chassis mode. This issue affects Juniper Networks Junos OS on EX and QFX Series: 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S4; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R1-S7, 18.3R2. This issue does not affect Juniper Networks Junos OS 12.3.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 6.8 MEDIUM
V2.0: 6.9 MEDIUM
CVE-2020-1617

This issue occurs on Juniper Networks Junos OS devices which do not support Advanced Forwarding Interface (AFI) / Advanced Forwarding Toolkit (AFT). Devices using AFI and AFT are not exploitable to this issue. An improper initialization of memory in the packet forwarding architecture in Juniper Networks Junos OS non-AFI/AFT platforms which may lead to a Denial of Service (DoS) vulnerability being exploited when a genuine packet is received and inspected by non-AFT/AFI sFlow and when the device is also configured with firewall policers. This first genuine packet received and inspected by sampled flow (sFlow) through a specific firewall policer will cause the device to reboot. After the reboot has completed, if the device receives and sFlow inspects another genuine packet seen through a specific firewall policer, the device will generate a core file and reboot. Continued inspection of these genuine packets will create an extended Denial of Service (DoS) condition. Depending on the method for service restoration, e.g. hard boot or soft reboot, a core file may or may not be generated the next time the packet is received and inspected by sFlow. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S9, 17.4R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.1 versions prior to 18.1R3-S9 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D30 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2 versions prior to 18.2R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.3 versions prior to 18.3R3 on PTX1000 and PTX10000 Series, QFX10000 Series. This issue is not applicable to Junos OS versions before 17.4R1. This issue is not applicable to Junos OS Evolved or Junos OS with Advanced Forwarding Toolkit (AFT) forwarding implementations which use a different implementation of sFlow. The following example information is unrelated to this issue and is provided solely to assist you with determining if you have AFT or not. Example: A Junos OS device which supports the use of EVPN signaled VPWS with Flexible Cross Connect uses the AFT implementation. Since this configuration requires support and use of the AFT implementation to support this configuration, the device is not vulnerable to this issue as the sFlow implementation is different using the AFT architecture. For further details about AFT visit the AFI / AFT are in the links below. If you are uncertain if you use the AFI/AFT implementation or not, there are configuration examples in the links below which you may use to determine if you are vulnerable to this issue or not. If the commands work, you are. If not, you are not. You may also use the Feature Explorer to determine if AFI/AFT is supported or not. If you are still uncertain, please contact your support resources.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2020-1615

The factory configuration for vMX installations, as shipped, includes default credentials for the root account. Without proper modification of these default credentials by the administrator, an attacker could exploit these credentials and access the vMX instance without authorization. This issue affects Juniper Networks Junos OS: 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on vMX; 17.2 versions prior to 17.2R3-S3 on vMX; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on vMX; 17.4 versions prior to 17.4R2-S9, 17.4R3 on vMX; 18.1 versions prior to 18.1R3-S9 on vMX; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on vMX; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D60 on vMX; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on vMX; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on vMX; 19.1 versions prior to 19.1R1-S4, 19.1R2, 19.1R3 on vMX; 19.2 versions prior to 19.2R1-S3, 19.2R2 on vMX; 19.3 versions prior to 19.3R1-S1, 19.3R2 on vMX.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2020-10188

utility.c in telnetd in netkit telnet through 0.17 allows remote attackers to execute arbitrary code via short writes or urgent data, because of a buffer overflow involving the netclear and nextitem functions.

Published: March 06, 2020; 10:15:14 AM -0500
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2020-1609

When a device using Juniper Network's Dynamic Host Configuration Protocol Daemon (JDHCPD) process on Junos OS or Junos OS Evolved which is configured in relay mode it vulnerable to an attacker sending crafted IPv6 packets who may then arbitrarily execute commands as root on the target device. This issue affects IPv6 JDHCPD services. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2*. and All versions prior to 19.3R1 on Junos OS Evolved. This issue do not affect versions of Junos OS prior to 15.1, or JDHCPD operating as a local server in non-relay mode.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.8 HIGH
V2.0: 8.3 HIGH
CVE-2020-1608

Receipt of a specific MPLS or IPv6 packet on the core facing interface of an MX Series device configured for Broadband Edge (BBE) service may trigger a kernel crash (vmcore), causing the device to reboot. The issue is specific to the processing of packets destined to BBE clients connected to MX Series subscriber management platforms. This issue affects MX Series running Juniper Networks Junos OS: 17.2 versions starting from17.2R2-S6, 17.2R3 and later releases, prior to 17.2R3-S3; 17.3 versions starting from 17.3R2-S4, 17.3R3-S2 and later releases, prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions starting from 17.4R2 and later releases, prior to 17.4R2-S7,17.4R3; 18.1 versions starting from 18.1R2-S3, 18.1R3 and later releases, prior to 18.1R3-S6; 18.2 versions starting from18.2R1-S1, 18.2R2 and later releases, prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R2-S6.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2020-1607

Insufficient Cross-Site Scripting (XSS) protection in J-Web may potentially allow a remote attacker to inject web script or HTML, hijack the target user's J-Web session and perform administrative actions on the Junos device as the targeted user. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90 on SRX Series; 14.1X53 versions prior to 14.1X53-D51 on EX and QFX Series; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.3 versions prior to 18.3R1-S6, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S2, 19.1R2.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2020-1606

A path traversal vulnerability in the Juniper Networks Junos OS device may allow an authenticated J-web user to read files with 'world' readable permission and delete files with 'world' writeable permission. This issue does not affect system files that can be accessed only by root user. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S13; 12.3X48 versions prior to 12.3X48-D85 on SRX Series; 14.1X53 versions prior to 14.1X53-D51; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.1 HIGH
V2.0: 6.5 MEDIUM
CVE-2020-1605

When a device using Juniper Network's Dynamic Host Configuration Protocol Daemon (JDHCPD) process on Junos OS or Junos OS Evolved which is configured in relay mode it vulnerable to an attacker sending crafted IPv4 packets who may then arbitrarily execute commands as root on the target device. This issue affects IPv4 JDHCPD services. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2*. and All versions prior to 19.3R1 on Junos OS Evolved. This issue do not affect versions of Junos OS prior to 15.1, or JDHCPD operating as a local server in non-relay mode.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.8 HIGH
V2.0: 8.3 HIGH
CVE-2020-1603

Specific IPv6 packets sent by clients processed by the Routing Engine (RE) are improperly handled. These IPv6 packets are designed to be blocked by the RE from egressing the RE. Instead, the RE allows these specific IPv6 packets to egress the RE, at which point a mbuf memory leak occurs within the Juniper Networks Junos OS device. This memory leak eventually leads to a kernel crash (vmcore), or the device hanging and requiring a power cycle to restore service, creating a Denial of Service (DoS) condition. During the time where mbufs are rising, yet not fully filled, some traffic from client devices may begin to be black holed. To be black holed, this traffic must match the condition where this traffic must be processed by the RE. Continued receipt and attempted egress of these specific IPv6 packets from the Routing Engine (RE) will create an extended Denial of Service (DoS) condition. Scenarios which have been observed are: 1. In a single chassis, single RE scenario, the device will hang without vmcore, or a vmcore may occur and then hang. In this scenario the device needs to be power cycled. 2. In a single chassis, dual RE scenario, the device master RE will fail over to the backup RE. In this scenario, the master and the backup REs need to be reset from time to time when they vmcore. There is no need to power cycle the device. 3. In a dual chassis, single RE scenario, the device will hang without vmcore, or a vmcore may occur and then hang. In this scenario, the two chassis' design relies upon some type of network level redundancy - VRRP, GRES, NSR, etc. - 3.a In a commanded switchover, where nonstop active routing (NSR) is enabled no session loss is observed. 4. In a dual chassis, dual chassis scenario, rely upon the RE to RE failover as stated in the second scenario. In the unlikely event that the device does not switch RE to RE gracefully, then the fallback position is to the network level services scenario in the third scenario. This issue affects: Juniper Networks Junos OS 16.1 versions prior to 16.1R7-S6; 16.1 version 16.1X70-D10 and later; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D50, 18.2X75-D410; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S6, 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect releases prior to Junos OS 16.1R1.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.6 HIGH
V2.0: 7.8 HIGH
CVE-2020-1602

When a device using Juniper Network's Dynamic Host Configuration Protocol Daemon (JDHCPD) process on Junos OS or Junos OS Evolved which is configured in relay mode it vulnerable to an attacker sending crafted IPv4 packets who may remotely take over the code execution of the JDHDCP process. This issue affect IPv4 JDHCPD services. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2*. and All versions prior to 19.3R1 on Junos OS Evolved. This issue do not affect versions of Junos OS prior to 15.1, or JDHCPD operating as a local server in non-relay mode.

Published: January 15, 2020; 4:15:12 AM -0500
V3.1: 8.8 HIGH
V2.0: 8.3 HIGH
CVE-2020-1601

Certain types of malformed Path Computation Element Protocol (PCEP) packets when received and processed by a Juniper Networks Junos OS device serving as a Path Computation Client (PCC) in a PCEP environment using Juniper's path computational element protocol daemon (pccd) process allows an attacker to cause the pccd process to crash and generate a core file thereby causing a Denial of Service (DoS). Continued receipt of this family of malformed PCEP packets will cause an extended Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S13, 15.1R7-S4; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238, 15.1X53-D496, 15.1X53-D592; 16.1 versions prior to 16.1R7-S4; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R2-S11, 17.1R3; 17.2 versions prior to 17.2R1-S9; 17.2 version 17.2R2 and later prior to 17.2R3-S2; 17.3 versions prior to 17.3R3-S3; 17.4 versions prior to 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R3-S2; 18.2 versions prior to 18.2R2-S6, 18.2R3; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R1-S2, 18.4R2. This issue does not affect releases of Junos OS prior to 15.1R1.

Published: January 15, 2020; 4:15:11 AM -0500
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2020-1600

In a Point-to-Multipoint (P2MP) Label Switched Path (LSP) scenario, an uncontrolled resource consumption vulnerability in the Routing Protocol Daemon (RPD) in Juniper Networks Junos OS allows a specific SNMP request to trigger an infinite loop causing a high CPU usage Denial of Service (DoS) condition. This issue affects both SNMP over IPv4 and IPv6. This issue affects: Juniper Networks Junos OS: 12.3X48 versions prior to 12.3X48-D90; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D238, 15.1X53-D592; 16.1 versions prior to 16.1R7-S5; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R3-S1; 17.2 versions prior to 17.2R3-S2; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R2-S4, 17.4R3; 18.1 versions prior to 18.1R3-S5; 18.2 versions prior to 18.2R3; 18.2X75 versions prior to 18.2X75-D50; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R2.

Published: January 15, 2020; 4:15:11 AM -0500
V3.1: 6.5 MEDIUM
V2.0: 6.8 MEDIUM
CVE-2019-0075

A vulnerability in the srxpfe process on Protocol Independent Multicast (PIM) enabled SRX series devices may lead to crash of the srxpfe process and an FPC reboot while processing (PIM) messages. Sustained receipt of these packets may lead to an extended denial of service condition. Affected releases are Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D80; 15.1X49 versions prior to 15.1X49-D160; 17.3 versions prior to 17.3R3-S7 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R2.

Published: October 09, 2019; 4:15:18 PM -0400
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-0074

A path traversal vulnerability in NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series devices with Next-Generation Routing Engine (NG-RE) allows a local authenticated user to read sensitive system files. This issue only affects NFX150 Series and QFX10K Series, EX9200 Series, MX Series and PTX Series with Next-Generation Routing Engine (NG-RE) which uses vmhost. This issue affects Juniper Networks Junos OS on NFX150 Series and QFX10K, EX9200 Series, MX Series and PTX Series with NG-RE and vmhost: 15.1F versions prior to 15.1F6-S12 16.1 versions starting from 16.1R6 and later releases, including the Service Releases, prior to 16.1R6-S6, 16.1R7-S3; 17.1 versions prior to 17.1R3; 17.2 versions starting from 17.2R1-S3, 17.2R3 and later releases, including the Service Releases, prior to 17.2R3-S1; 17.3 versions starting from 17.3R1-S1, 17.3R2 and later releases, including the Service Releases, prior to 17.3R3-S3; 17.4 versions starting from 17.4R1 and later releases, including the Service Releases, prior to 17.4R1-S6, 17.4R2-S2, 17.4R3; 18.1 versions prior to 18.1R2-S4, 18.1R3-S3; 18.2 versions prior to 18.2R2; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S2, 18.3R2; 18.4 versions prior to 18.4R1-S1, 18.4R2. This issue does not affect: Juniper Networks Junos OS 15.1 and 16.2.

Published: October 09, 2019; 4:15:18 PM -0400
V3.1: 5.5 MEDIUM
V2.0: 2.1 LOW
CVE-2019-0073

The PKI keys exported using the command "run request security pki key-pair export" on Junos OS may have insecure file permissions. This may allow another user on the Junos OS device with shell access to read them. This issue affects: Juniper Networks Junos OS 15.1X49 versions prior to 15.1X49-D180; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2.

Published: October 09, 2019; 4:15:18 PM -0400
V3.1: 7.1 HIGH
V2.0: 2.1 LOW
CVE-2019-0069

On EX4600, QFX5100 Series, NFX Series, QFX10K Series, QFX5110, QFX5200 Series, QFX5110, QFX5200, QFX10K Series, vSRX, SRX1500, SRX4000 Series, vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series, when the user uses console management port to authenticate, the credentials used during device authentication are written to a log file in clear text. This issue does not affect users that are logging-in using telnet, SSH or J-web to the management IP. This issue affects ACX, NFX, SRX, EX and QFX platforms with the Linux Host OS architecture, it does not affect other SRX and EX platforms that do not use the Linux Host OS architecture. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D110 on vSRX, SRX1500, SRX4000 Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5110, QFX5200 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 17.1 versions prior to 17.1R2-S8, 17.1R3, on QFX5110, QFX5200, QFX10K Series; 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3 on QFX5110, QFX5200, QFX10K Series; 17.3 versions prior to 17.3R2 on vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series; 14.1X53 versions prior to 14.1X53-D47 on ACX5000, EX4600, QFX5100 Series; 15.1 versions prior to 15.1R7 on ACX5000, EX4600, QFX5100 Series; 16.1R7 versions prior to 16.1R7 on ACX5000, EX4600, QFX5100 Series; 17.1 versions prior to 17.1R2-S10, 17.1R3 on ACX5000, EX4600, QFX5100 Series; 17.2 versions prior to 17.2R3 on ACX5000, EX4600, QFX5100 Series; 17.3 versions prior to 17.3R3 on ACX5000, EX4600, QFX5100 Series; 17.4 versions prior to 17.4R2 on ACX5000, EX4600, QFX5100 Series; 18.1 versions prior to 18.1R2 on ACX5000, EX4600, QFX5100 Series; 15.1X53 versions prior to 15.1X53-D496 on NFX Series, 17.2 versions prior to 17.2R3-S1 on NFX Series; 17.3 versions prior to 17.3R3-S4 on NFX Series; 17.4 versions prior to 17.4R2-S4, 17.4R3 on NFX Series, 18.1 versions prior to 18.1R3-S4 on NFX Series; 18.2 versions prior to 18.2R2-S3, 18.2R3 on NFX Series; 18.3 versions prior to 18.3R1-S3, 18.3R2 on NFX Series; 18.4 versions prior to 18.4R1-S1, 18.4R2 on NFX Series.

Published: October 09, 2019; 4:15:17 PM -0400
V3.1: 5.5 MEDIUM
V2.0: 2.1 LOW
CVE-2019-0068

The SRX flowd process, responsible for packet forwarding, may crash and restart when processing specific multicast packets. By continuously sending the specific multicast packets, an attacker can repeatedly crash the flowd process causing a sustained Denial of Service. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D90; 15.1X49 versions prior to 15.1X49-D180; 17.3 versions; 17.4 versions prior to 17.4R2-S5, 17.4R3; 18.1 versions prior to 18.1R3-S6; 18.2 versions prior to 18.2R2-S4, 18.2R3; 18.3 versions prior to 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S1, 19.1R2.

Published: October 09, 2019; 4:15:17 PM -0400
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM