Vuln ID Summary CVSS Severity
CVE-2019-11087

Insufficient input validation in the subsystem for Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45, 13.0.10 and 14.0.10; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow a privileged user to potentially enable escalation of privilege, information disclosure or denial of service via local access.

Published: December 18, 2019; 5:15:12 PM -0500
V4.0:(not available)
V3.1: 6.7 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2019-11086

Insufficient input validation in subsystem for Intel(R) AMT before version 12.0.45 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.

Published: December 18, 2019; 5:15:12 PM -0500
V4.0:(not available)
V3.1: 6.8 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2019-0169

Heap overflow in subsystem in Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow an unauthenticated user to potentially enable escalation of privileges, information disclosure or denial of service via adjacent access.

Published: December 18, 2019; 5:15:11 PM -0500
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 5.8 MEDIUM
CVE-2019-0168

Insufficient input validation in the subsystem for Intel(R) CSME before versions 11.8.70, 12.0.45 and 13.0.10; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow a privileged user to potentially enable information disclosure via local access.

Published: December 18, 2019; 5:15:11 PM -0500
V4.0:(not available)
V3.1: 4.4 MEDIUM
V2.0: 2.1 LOW
CVE-2019-0166

Insufficient input validation in the subsystem for Intel(R) AMT before versions 11.8.70, 11.11.70, 11.22.70 and 12.0.45 may allow an unauthenticated user to potentially enable information disclosure via network access.

Published: December 18, 2019; 5:15:11 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-0165

Insufficient Input validation in the subsystem for Intel(R) CSME before versions 12.0.45,13.0.10 and 14.0.10 may allow a privileged user to potentially enable denial of service via local access.

Published: December 18, 2019; 5:15:11 PM -0500
V4.0:(not available)
V3.1: 4.4 MEDIUM
V2.0: 2.1 LOW
CVE-2019-0131

Insufficient input validation in subsystem in Intel(R) AMT before versions 11.8.70, 11.11.70, 11.22.70 and 12.0.45 may allow an unauthenticated user to potentially enable denial of service or information disclosure via adjacent access.

Published: December 18, 2019; 5:15:11 PM -0500
V4.0:(not available)
V3.1: 8.1 HIGH
V2.0: 4.8 MEDIUM
CVE-2019-5487

An improper access control vulnerability exists in Gitlab EE <v12.3.3, <v12.2.7, & <v12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2019-5486

A authentication bypass vulnerability exists in GitLab CE/EE <v12.3.2, <v12.2.6, and <v12.1.10 in the Salesforce login integration that could be used by an attacker to create an account that bypassed domain restrictions and email verification requirements.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-5469

An IDOR vulnerability exists in GitLab <v12.1.2, <v12.0.4, and <v11.11.6 that allowed uploading files from project archive to replace other users files potentially allowing an attacker to replace project binaries or other uploaded assets.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 6.5 MEDIUM
V2.0: 5.5 MEDIUM
CVE-2019-5080

An exploitable denial-of-service vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC 200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A single packet can cause a denial of service and weaken credentials resulting in the default documented credentials being applied to the device. An attacker can send an unauthenticated packet to trigger this vulnerability.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 9.1 CRITICAL
V2.0: 6.4 MEDIUM
CVE-2019-5079

An exploitable heap buffer overflow vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause a heap buffer overflow, potentially resulting in code execution. An attacker can send unauthenticated packets to trigger this vulnerability.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2019-5078

An exploitable denial of service vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause a denial of service, resulting in the device entering an error state where it ceases all network communications. An attacker can send unauthenticated packets to trigger this vulnerability.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 9.1 CRITICAL
V2.0: 9.4 HIGH
CVE-2019-5075

An exploitable stack buffer overflow vulnerability exists in the command line utility getcouplerdetails of WAGO PFC200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets sent to the iocheckd service "I/O-Check" can cause a stack buffer overflow in the sub-process getcouplerdetails, resulting in code execution. An attacker can send unauthenticated packets to trigger this vulnerability.

Published: December 18, 2019; 4:15:14 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2019-5073

An exploitable information exposure vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause an external tool to fail, resulting in uninitialized stack data to be copied to the response packet buffer. An attacker can send unauthenticated packets to trigger this vulnerability.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2019-1387

An issue was found in Git before v2.24.1, v2.23.1, v2.22.2, v2.21.1, v2.20.2, v2.19.3, v2.18.2, v2.17.3, v2.16.6, v2.15.4, and v2.14.6. Recursive clones are currently affected by a vulnerability that is caused by too-lax validation of submodule names, allowing very targeted attacks via remote code execution in recursive clones.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2019-19724

Insecure permissions (777) are set on $HOME/.singularity when it is newly created by Singularity (version from 3.3.0 to 3.5.1), which could lead to an information leak, and malicious redirection of operations performed against Sylabs cloud services.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-18997

The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-18996

Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 4.4 MEDIUM
CVE-2019-18995

The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.

Published: December 18, 2019; 4:15:13 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM