Search Results (Refine Search)
- Results Type: Overview
Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2019-13047 |
kernel/sys/syscall.c in ToaruOS through 1.10.9 has incorrect access control in sys_sysfunc case 9 for TOARU_SYS_FUNC_SETHEAP, allowing arbitrary kernel pages to be mapped into user land, leading to root access. Published: June 29, 2019; 11:15:09 AM -0400 |
V4.0:(not available) V3.0: 7.8 HIGH V2.0: 7.2 HIGH |
CVE-2019-13046 |
linker/linker.c in ToaruOS through 1.10.9 has insecure LD_LIBRARY_PATH handling in setuid applications. Published: June 29, 2019; 11:15:09 AM -0400 |
V4.0:(not available) V3.0: 7.8 HIGH V2.0: 7.2 HIGH |
CVE-2019-13045 |
Irssi before 1.0.8, 1.1.x before 1.1.3, and 1.2.x before 1.2.1, when SASL is enabled, has a use after free when sending SASL login to the server. Published: June 29, 2019; 10:15:09 AM -0400 |
V4.0:(not available) V3.0: 8.1 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-13038 |
mod_auth_mellon through 0.14.2 has an Open Redirect via the login?ReturnTo= substring, as demonstrated by omitting the // after http: in the target URL. Published: June 29, 2019; 10:15:09 AM -0400 |
V4.0:(not available) V3.1: 6.1 MEDIUM V2.0: 4.3 MEDIUM |
CVE-2019-13035 |
Artica Pandora FMS 7.0 NG before 735 suffers from local privilege escalation due to improper permissions on C:\PandoraFMS and its sub-folders, allowing standard users to create new files. Moreover, the Apache service httpd.exe will try to execute cmd.exe from C:\PandoraFMS (the current directory) as NT AUTHORITY\SYSTEM upon web requests to the portal. This will effectively allow non-privileged users to escalate privileges to NT AUTHORITY\SYSTEM. Published: June 29, 2019; 9:15:08 AM -0400 |
V4.0:(not available) V3.0: 7.8 HIGH V2.0: 7.2 HIGH |
CVE-2019-13032 |
An issue was discovered in FlightCrew v0.9.2 and earlier. A NULL pointer dereference occurs in GetRelativePathToNcx() or GetRelativePathsToXhtmlDocuments() when a NULL pointer is passed to xc::XMLUri::isValidURI(). This affects third-party software (not Sigil) that uses FlightCrew as a library. Published: June 28, 2019; 7:15:09 PM -0400 |
V4.0:(not available) V3.0: 5.5 MEDIUM V2.0: 4.3 MEDIUM |
CVE-2019-13031 |
LemonLDAP::NG before 1.9.20 has an XML External Entity (XXE) issue when submitting a notification to the notification server. By default, the notification server is not enabled and has a "deny all" rule. Published: June 28, 2019; 7:15:09 PM -0400 |
V4.0:(not available) V3.0: 8.1 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-13028 |
An incorrect implementation of a local web server in eID client (Windows version before 3.1.2, Linux version before 3.0.3) allows remote attackers to execute arbitrary code (.cgi, .pl, or .php) or delete arbitrary files via a crafted HTML page. This is a product from the Ministry of Interior of the Slovak Republic. Published: June 28, 2019; 6:15:08 PM -0400 |
V4.0:(not available) V3.0: 8.8 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-10993 |
In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2019-10991 |
In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2019-10989 |
In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 9.8 CRITICAL V2.0: 7.5 HIGH |
CVE-2019-10987 |
In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 8.8 HIGH V2.0: 6.8 MEDIUM |
CVE-2019-10985 |
In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 9.1 CRITICAL V2.0: 6.4 MEDIUM |
CVE-2019-10983 |
In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.1: 7.5 HIGH V2.0: 5.0 MEDIUM |
CVE-2019-10964 |
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery. Published: June 28, 2019; 5:15:11 PM -0400 |
V4.0:(not available) V3.0: 8.8 HIGH V2.0: 5.8 MEDIUM |
CVE-2019-10175 |
A flaw was found in the containerized-data-importer in virt-cdi-cloner, version 1.4, where the host-assisted cloning feature does not determine whether the requesting user has permission to access the Persistent Volume Claim (PVC) in the source namespace. This could allow users to clone any PVC in the cluster into their own namespace, effectively allowing access to other user's data. Published: June 28, 2019; 4:15:10 PM -0400 |
V4.0:(not available) V3.1: 6.5 MEDIUM V2.0: 4.0 MEDIUM |
CVE-2019-9843 |
In DiffPlug Spotless before 1.20.0 (library and Maven plugin) and before 3.20.0 (Gradle plugin), the XML parser would resolve external entities over both HTTP and HTTPS and didn't respect the resolveExternalEntities setting. For example, this allows disclosure of file contents to a MITM attacker if a victim performs a spotlessApply operation on an untrusted XML file. Published: June 28, 2019; 2:15:15 PM -0400 |
V4.0:(not available) V3.0: 7.5 HIGH V2.0: 5.1 MEDIUM |
CVE-2019-12932 |
A stored XSS vulnerability was found in SeedDMS 5.1.11 due to poorly escaping the search result in the autocomplete search form placed in the header of out/out.Viewfolder.php. Published: June 28, 2019; 2:15:11 PM -0400 |
V4.0:(not available) V3.0: 6.1 MEDIUM V2.0: 4.3 MEDIUM |
CVE-2018-20814 |
An XSS issue was found with Psaldownload.cgi in Pulse Secure Pulse Connect Secure (PCS) 8.3R2 before 8.3R2 and Pulse Policy Secure (PPS) 5.4RX before 5.4R2. This is not applicable to PCS 8.1RX or PPS 5.2RX. Published: June 28, 2019; 2:15:11 PM -0400 |
V4.0:(not available) V3.0: 6.1 MEDIUM V2.0: 4.3 MEDIUM |
CVE-2018-20813 |
An input validation issue has been found with login_meeting.cgi in Pulse Secure Pulse Connect Secure 8.3RX before 8.3R2. Published: June 28, 2019; 2:15:11 PM -0400 |
V4.0:(not available) V3.0: 9.8 CRITICAL V2.0: 7.5 HIGH |