U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
There are 244,356 matching records.
Displaying matches 130,221 through 130,240.
Vuln ID Summary CVSS Severity
CVE-2019-3826

A stored, DOM based, cross-site scripting (XSS) flaw was found in Prometheus before version 2.7.1. An attacker could exploit this by convincing an authenticated user to visit a crafted URL on a Prometheus server, allowing for the execution and persistent storage of arbitrary scripts.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2019-3804

It was found that cockpit before version 184 used glib's base64 decode functionality incorrectly resulting in a denial of service attack. An unauthenticated attacker could send a specially crafted request with an invalid base64-encoded cookie which could cause the web service to crash.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2019-3606

Data Leakage Attacks vulnerability in the web portal component when in an MDR pair in McAfee Network Security Management (NSM) 9.1 < 9.1.7.75 (Update 4) and 9.2 < 9.2.7.31 Update2 allows administrators to view configuration information in plain text format via the GUI or GUI terminal commands.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 4.1 MEDIUM
V2.0: 1.9 LOW
CVE-2019-3597

Authentication Bypass vulnerability in McAfee Network Security Manager (NSM) 9.1 < 9.1.7.75.2 and 9.2 < 9.2.7.31 (9.2 Update 2) allows unauthenticated users to gain administrator rights via incorrect handling of expired GUI sessions.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2019-10068

An issue was discovered in Kentico 12.0.x before 12.0.15, 11.0.x before 11.0.48, 10.0.x before 10.0.52, and 9.x versions. Due to a failure to validate security headers, it was possible for a specially crafted request to the staging service to bypass the initial authentication and proceed to deserialize user-controlled .NET object input. This deserialization then led to unauthenticated remote code execution on the server where the Kentico instance was hosted.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2018-16856

In a default Red Hat Openstack Platform Director installation, openstack-octavia before versions openstack-octavia 2.0.2-5 and openstack-octavia-3.0.1-0.20181009115732 creates log files that are readable by all users. Sensitive information such as private keys can appear in these log files allowing for information exposure.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2013-2805

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2010-5305

The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services.

Published: March 26, 2019; 2:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2019-9061

An issue was discovered in CMS Made Simple 2.2.8. In the module ModuleManager (in the file action.installmodule.php), it is possible to reach an unserialize call with untrusted input and achieve authenticated object injection by using the "install module" feature.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-9059

An issue was discovered in CMS Made Simple 2.2.8. It is possible, with an administrator account, to achieve command injection by modifying the path of the e-mail executable in Mail Settings, setting "sendmail" in the "Mailer" option, and launching the "Forgot your password" feature.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.0: 7.2 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-9058

An issue was discovered in CMS Made Simple 2.2.8. In the administrator page admin/changegroupperm.php, it is possible to send a crafted value in the sel_groups parameter that leads to authenticated object injection.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.1: 7.2 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-9057

An issue was discovered in CMS Made Simple 2.2.8. In the module FilePicker, it is possible to reach an unserialize call with an untrusted parameter, and achieve authenticated object injection.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-9055

An issue was discovered in CMS Made Simple 2.2.8. In the module DesignManager (in the files action.admin_bulk_css.php and action.admin_bulk_template.php), with an unprivileged user with Designer permission, it is possible reach an unserialize call with a crafted value in the m1_allparms parameter, and achieve object injection.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.5 MEDIUM
CVE-2019-9053

An issue was discovered in CMS Made Simple 2.2.8. It is possible with the News module, through a crafted URL, to achieve unauthenticated blind time-based SQL injection via the m1_idlist parameter.

Published: March 26, 2019; 1:29:01 PM -0400
V4.0:(not available)
V3.0: 8.1 HIGH
V2.0: 6.8 MEDIUM
CVE-2014-5401

Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1.

Published: March 26, 2019; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2013-2807

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Published: March 26, 2019; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2013-2806

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Published: March 26, 2019; 1:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2019-7646

CentOS-WebPanel.com (aka CWP) CentOS Web Panel through 0.9.8.763 is vulnerable to Stored/Persistent XSS for the "Package Name" field via the add_package module parameter.

Published: March 26, 2019; 12:29:01 PM -0400
V4.0:(not available)
V3.0: 4.8 MEDIUM
V2.0: 3.5 LOW
CVE-2018-19856

GitLab CE/EE before 11.3.12, 11.4.x before 11.4.10, and 11.5.x before 11.5.3 allows Directory Traversal in Templates API.

Published: March 26, 2019; 12:29:00 PM -0400
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2014-5433

An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.

Published: March 26, 2019; 12:29:00 PM -0400
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH