U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Search Type: Search All
There are 236,671 matching records.
Displaying matches 126,221 through 126,240.
Vuln ID Summary CVSS Severity
CVE-2018-1813

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 uses incomplete blacklisting for input validation which allows attackers to bypass application controls resulting in direct impact to the system and data integrity. IBM X-Force ID: 150017.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 6.5 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2018-1805

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 generates an error message that includes sensitive information about its environment, users, or associated data. IBM X-Force ID: 149704.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 4.3 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2018-1804

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 does not set the secure attribute on authorization tokens or session cookies. This could allow an attacker to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 149703.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 3.7 LOW
V2.0: 4.3 MEDIUM
CVE-2018-1803

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 could allow a remote attacker to hijack the clicking action of the victim. By persuading a victim to visit a malicious Web site, a remote attacker could exploit this vulnerability to hijack the victim's click actions and possibly launch further attacks against the victim. IBM X-Force ID: 149702.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2018-1740

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 148419.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2018-1667

IBM DataPower Gateway 7.6.0.0 through 7.6.0.10, 7.5.2.0 through 7.5.2.17, 7.5.1.0 through 7.5.1.17, 7.5.0.0 through 7.5.0.18, and 7.7.0.0 through 7.7.1.3 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 144893.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2018-1665

IBM DataPower Gateway 7.6.0.0 through 7.6.0.10, 7.5.2.0 through 7.5.2.17, 7.5.1.0 through 7.5.1.17, 7.5.0.0 through 7.5.0.18, and 7.7.0.0 through 7.7.1.3 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 144891.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-16557

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.1: 8.2 HIGH
V2.0: 7.8 HIGH
CVE-2018-16556

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2018-1653

IBM Security Access Manager Appliance 9.0.1.0, 9.0.2.0, 9.0.3.0, 9.0.4.0, and 9.0.5.0 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 144726.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 5.4 MEDIUM
V2.0: 3.5 LOW
CVE-2018-13815

A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-13814

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2018-13813

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 8.1 HIGH
V2.0: 5.8 MEDIUM
CVE-2018-13812

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-13811

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 5.5 MEDIUM
V2.0: 2.1 LOW
CVE-2018-13804

A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 8.1 HIGH
V2.0: 9.3 HIGH
CVE-2017-1268

IBM Security Guardium 10 and 10.5 uses a one-way cryptographic hash against an input that should not be reversible, such as a password, but the software does not also use a salt as part of the input. IBM X-Force ID: 124743.

Published: December 13, 2018; 11:29:00 AM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 2.1 LOW
CVE-2018-8033

In Apache OFBiz 16.11.01 to 16.11.04, the OFBiz HTTP engine (org.apache.ofbiz.service.engine.HttpEngine.java) handles requests for HTTP services via the /webtools/control/httpService endpoint. Both POST and GET requests to the httpService endpoint may contain three parameters: serviceName, serviceMode, and serviceContext. The exploitation occurs by having DOCTYPEs pointing to external references that trigger a payload that returns secret information from the host.

Published: December 13, 2018; 9:29:00 AM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2018-7691

A potential Remote Unauthorized Access in Micro Focus Fortify Software Security Center (SSC), versions 17.10, 17.20, 18.10 this exploitation could allow Remote Unauthorized Access

Published: December 13, 2018; 9:29:00 AM -0500
V4.0:(not available)
V3.0: 6.5 MEDIUM
V2.0: 4.0 MEDIUM