Vuln ID Summary CVSS Severity
CVE-2016-9343

An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 10.0 CRITICAL
V2.0: 7.5 HIGH
CVE-2016-9339

An issue was discovered in INTERSCHALT Maritime Systems VDR G4e Versions 5.220 and prior. External input is used to construct paths to files and directories without properly neutralizing special elements within the pathname that could allow an attacker to read files on the system, a Path Traversal.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2016-9338

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 2.7 LOW
V2.0: 4.0 MEDIUM
CVE-2016-9337

An issue was discovered in Tesla Motors Model S automobile, all firmware versions before version 7.1 (2.36.31) with web browser functionality enabled. The vehicle's Gateway ECU is susceptible to commands that may allow an attacker to install malicious software allowing the attacker to send messages to the vehicle's CAN bus, a Command Injection.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 6.8 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2016-9334

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 7.3 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-9333

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2016-9332

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2016-8567

An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0: 7.5 HIGH
CVE-2016-8566

An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0: 4.6 MEDIUM
CVE-2016-8379

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.1 HIGH
V2.0: 4.3 MEDIUM
CVE-2016-8378

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards for protecting credentials.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 5.0 MEDIUM
CVE-2016-8377

An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.0 HIGH
V2.0: 6.0 MEDIUM
CVE-2016-8376

An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. This non-validated redirect/non-validated forward (OPEN REDIRECT) allows chaining with authenticated vulnerabilities.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 5.8 MEDIUM
CVE-2016-8374

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2016-8372

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.1 HIGH
V2.0: 4.3 MEDIUM
CVE-2016-8370

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-8369

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request (CROSS-SITE REQUEST FORGERY).

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2016-8368

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.6 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-8367

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2016-8364

An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH