Vuln ID Summary CVSS Severity
CVE-2016-8378

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards for protecting credentials.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 5.0 MEDIUM
CVE-2016-8377

An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.0 HIGH
V2.0: 6.0 MEDIUM
CVE-2016-8376

An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. This non-validated redirect/non-validated forward (OPEN REDIRECT) allows chaining with authenticated vulnerabilities.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 6.1 MEDIUM
V2.0: 5.8 MEDIUM
CVE-2016-8374

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2016-8372

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.1 HIGH
V2.0: 4.3 MEDIUM
CVE-2016-8370

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-8369

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request (CROSS-SITE REQUEST FORGERY).

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 8.8 HIGH
V2.0: 6.8 MEDIUM
CVE-2016-8368

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 8.6 HIGH
V2.0: 5.0 MEDIUM
CVE-2016-8367

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2016-8364

An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 9.8 CRITICAL
V2.0: 10.0 HIGH
CVE-2016-8363

An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. User is able to execute arbitrary OS commands on the server.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 10.0 CRITICAL
V2.0: 7.5 HIGH
CVE-2016-8362

An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. Any user is able to download log files by accessing a specific URL.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 6.5 MEDIUM
V2.0: 4.0 MEDIUM
CVE-2016-8361

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication.

Published: February 13, 2017; 4:59:01 PM -0500
V4.0:(not available)
V3.0: 8.6 HIGH
V2.0: 7.5 HIGH
CVE-2016-8360

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 8.1 HIGH
V2.0: 6.8 MEDIUM
CVE-2016-8359

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.1: 6.1 MEDIUM
V2.0: 4.3 MEDIUM
CVE-2016-8357

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. A user with read-only access can send commands to the software and the application will accept those commands. This would allow an attacker with read-only access to make changes within the application.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 7.1 HIGH
V2.0: 5.5 MEDIUM
CVE-2016-8356

An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. The web server URL inputs are not sanitized correctly, which may allow cross-site scripting vulnerabilities.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 8.2 HIGH
V2.0: 4.3 MEDIUM
CVE-2016-8354

An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 7.0 HIGH
V2.0: 5.1 MEDIUM
CVE-2016-8353

An issue was discovered in OSIsoft PI Web API 2015 R2 (Version 1.5.1). There is a weakness in this product that may allow an attacker to access the PI system without the proper permissions.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 6.4 MEDIUM
V2.0: 5.5 MEDIUM
CVE-2016-8352

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Published: February 13, 2017; 4:59:00 PM -0500
V4.0:(not available)
V3.0: 10.0 CRITICAL
V2.0: 7.5 HIGH