U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
There are 243,750 matching records.
Displaying matches 24,701 through 24,720.
Vuln ID Summary CVSS Severity
CVE-2023-49991

Espeak-ng 1.52-dev was discovered to contain a Stack Buffer Underflow via the function CountVowelPosition at synthdata.c.

Published: December 12, 2023; 9:15:07 AM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0:(not available)
CVE-2023-49990

Espeak-ng 1.52-dev was discovered to contain a buffer-overflow via the function SetUpPhonemeTable at synthdata.c.

Published: December 12, 2023; 9:15:07 AM -0500
V4.0:(not available)
V3.1: 5.3 MEDIUM
V2.0:(not available)
CVE-2020-12612

An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When specifying a program to elevate, it can typically be found within the Program Files (x86) folder and therefore uses the %ProgramFiles(x86)% environment variable. However, when this same policy gets pushed to a 32bit machine, this environment variable does not exist. Therefore, since the standard user can create a user level environment variable, they can repoint this variable to any folder the user has full control of. Then, the folder structure can be created in such a way that a rule matches and arbitrary code runs elevated.

Published: December 12, 2023; 9:15:07 AM -0500
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0:(not available)
CVE-2020-12615

An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.

Published: December 12, 2023; 8:15:06 AM -0500
V4.0:(not available)
V3.1: 7.8 HIGH
V2.0:(not available)
CVE-2023-49692

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V3.0.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.

Published: December 12, 2023; 7:15:16 AM -0500
V4.0:(not available)
V3.1: 6.7 MEDIUM
V2.0:(not available)
CVE-2023-49691

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V3.0.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.

Published: December 12, 2023; 7:15:15 AM -0500
V4.0:(not available)
V3.1: 6.7 MEDIUM
V2.0:(not available)
CVE-2023-48431

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).

Published: December 12, 2023; 7:15:15 AM -0500
V4.0:(not available)
V3.1: 8.6 HIGH
V2.0:(not available)
CVE-2023-48430

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

Published: December 12, 2023; 7:15:15 AM -0500
V4.0:(not available)
V3.1: 2.7 LOW
V2.0:(not available)
CVE-2023-48429

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.

Published: December 12, 2023; 7:15:15 AM -0500
V4.0:(not available)
V3.1: 2.7 LOW
V2.0:(not available)
CVE-2023-48428

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.

Published: December 12, 2023; 7:15:14 AM -0500
V4.0:(not available)
V3.1: 7.2 HIGH
V2.0:(not available)
CVE-2023-48427

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.

Published: December 12, 2023; 7:15:14 AM -0500
V4.0:(not available)
V3.1: 9.8 CRITICAL
V2.0:(not available)
CVE-2023-46285

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

Published: December 12, 2023; 7:15:14 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2023-46284

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Published: December 12, 2023; 7:15:14 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2023-46283

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Published: December 12, 2023; 7:15:14 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2023-46282

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

Published: December 12, 2023; 7:15:13 AM -0500
V4.0:(not available)
V3.1: 6.1 MEDIUM
V2.0:(not available)
CVE-2023-46281

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.

Published: December 12, 2023; 7:15:13 AM -0500
V4.0:(not available)
V3.1: 8.8 HIGH
V2.0:(not available)
CVE-2023-46156

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations.

Published: December 12, 2023; 7:15:13 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2023-38380

A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.

Published: December 12, 2023; 7:15:11 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2022-47375

A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.

Published: December 12, 2023; 7:15:10 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)
CVE-2022-47374

A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.

Published: December 12, 2023; 7:15:10 AM -0500
V4.0:(not available)
V3.1: 7.5 HIGH
V2.0:(not available)